Auto Clear of Alarm / Error / ACA
If this parameter is set to nO:
The alarm status will
not
disappear automatically even if the condition which
caused the alarm is no longer valid or present .
If set to yES:
As soon as the condition which caused the alarm is no longer valid or present, the
alarm status will automatically change back to inactive . There will be no trace of
the alarm having occurred .
In general, Glass Door Merchandise applications will be set to yES and Commercial
Fridges and Freezers set to nO . For example, if the temperature goes too high for
a period there may be food safety considerations in a freezer containing food but
not in a fridge with cold drinks .
7.3 Compressor /
CoP
ERC menu
code
Default
Min
Max
Unit
Conv
Unit
Scale
Default Access
Shop Ser OEM
Compressor
CoP
Min run time
Crt
0
0
30
no
min
1
-- RW RW
Min Stop time
CSt
0
0
30
no
min
1
-- RW RW
Max Off time
Cot
0
0
480
no
min
1
-- -- RW
Error run time
Ert
0
0
60
no
min
1
-- -- RW
Error stop time
ESt
1
0
60
no
min
1
-- -- RW
Minimum cut-in voltage
uLi
0
0
270
no
Vac
1
-- -- RW
Minimum cut-out voltage
uLo
0
0
270
no
Vac
1
-- -- RW
Maximum voltage
uHi
270
0
270
no
Vac
1
-- -- RW
Power On Delay
Pod
300
0
300
no
Sec
1
-- RW RW
Power Factor
PFA
0
-90
90
no
Degree
1
-- -- RW
Initial cut in
iCi
no
no
yes
no
1
-- R- RW
Compressor door open delay
Cdd
0
0
15
no
min
1
-- RO RW
Danfoss ERC 102
Hold 3 sec: Menu
1 Click: Variable direct function, e.g.ECO/Night mode
1 Click: Variable direct function, e.g. light
Sub function: Up
1 Click: Temperature setpoint
Sub function: Down
Sub function: Back
Sub function: OK
ERC Front and Button Functionallity:
1 Click: Temperature setpoint
Danfoss ERC 102
Hold 3 sec: Menu
1 Click: Variable direct function, e.g.ECO/Night mode
1 Click: Variable direct function, e.g. light
Sub function: Up
1 Click: Temperature setpoint
Sub function: Down
Sub function: Back
Sub function: OK
ERC Front and Button Functionallity:
1 Click: Temperature setpoint
ERC
102 Reference manual – 7 PARAMETERS