152
•
Troubleshooting
Linea2 5GigE Series Camera
Device Available with Operational Issues
This section considers issues with cabling, Ethernet switches, multiple cameras and camera
exposure. Information concerning Teledyne DALSA
’s
Network Configuration Tool and other
networking considerations, is available in the
Teledyne DALSA Network Imaging manual
.
Firmware Updates
As a general rule any Linea2 5GigE installation must include the firmware update procedure (Refer
to File Access Control Category section for feature descriptions). Linea2 5GigE camera firmware
that does not match a newer version of installed GigE Vision software is likely to have
unpredictable behavior.
•
Linea2 5GigE is not found by the device discovery process.
•
Linea2 5GigE is found by the Sapera GigE Server but an application such as CamExpert does
not see the camera.
•
A Linea2 5GigE that had a fault with a firmware update will automatically recover by booting
with the previous firmware version.
Important
: New cameras installed in previously deployed systems are fully backward
compatible with the older vision application.
Power Failure During a Firmware Update
–
Now What?
Don't panic! There is far greater chance that the host computer OS is damaged during a power
failure than any permanent problems with the Linea2 5GigE. When power returns and the host
computer system has started, follow this procedure.
•
Connect power to the Linea2 5GigE. The camera processor knows that the firmware update
failed.
•
The Linea2 5GigE will boot with the previous version of firmware and will operate normally.
•
Perform the firmware update procedure again.
Содержание Linea2 5GigE
Страница 32: ...Linea2 5GigE Series Camera Linea2 5GigE Camera Quick Start 25 Figure 12 The Multiformat Buffer View list...
Страница 95: ...88 Operational Reference Linea2 5GigE Series Camera Figure 63 Sapera Explorer...
Страница 163: ...156 Revision History Linea2 5GigE Series Camera Revision History Revision Change Date 00 Initial release 13 April 2023...