Linea2 5GigE Series Camera
Network Overview & Tools
•
121
Persistent IP
•
Allows the user full control of IP address assignment on the network.
•
The camera is forced a static IP address. The NIC IP address must be the same to access the
camera.
•
If the camera is connected to a network with a different subnet, it cannot be accessed.
•
Use Teledyne DALSA
’s Network Configuration Tool
to set a persistent IP address. Refer to
Teledyne DALSA
’s
Network Imaging manual.
•
Example of a Persistent IP address assignment on a class B network:
•
NIC Subnet = 192.168.1.1
•
Subnet Mask = 255.255.0.0
•
Persistent IP = 192.168.1.2
•
Default Gateway = 0.0.0.0
Warning:
An incorrect IP address assignment may block connecting to the camera.
Use Teledyne DALSA
’s
Network Configuration tool to recover a camera with an
unknown persistent IP
. It will reset the camera’s
factory default mode, DHCP/LLA.
The camera’s MAC
address displayed on the exterior camera is required to perform
this function.
•
For GigE Vision applications, the FORCEIP command is used to force a new persistent IP or to
change the IP configuration protocol. The camera’s MAC address must be known to use the
FORCEIP command.
•
The following illustration shows a functional computer setup with three NIC ports but no DHCP
server. Two NIC ports are used for private GigE Vision networks. The first uses the default LLA
mode for IP addresses, the second NIC and cameras connected to it are configured with
persistent IP addresses. An application on the computer can control each camera, on each
subnet, without conflict.
Содержание Linea2 5GigE
Страница 32: ...Linea2 5GigE Series Camera Linea2 5GigE Camera Quick Start 25 Figure 12 The Multiformat Buffer View list...
Страница 95: ...88 Operational Reference Linea2 5GigE Series Camera Figure 63 Sapera Explorer...
Страница 163: ...156 Revision History Linea2 5GigE Series Camera Revision History Revision Change Date 00 Initial release 13 April 2023...