Appendix A: GenICam Commands
61
Acquisition and Transfer Control Feature Descriptions
Display Name
Feature
Description
Device Version
& View
Acquisition Mode
Continuous
AcquisitionMode
The device acquisition mode defines the number of frames to
capture during an acquisition and the way it stops
Only continuous mode is currently available
1.00
Beginner
DFNC
Acquisition Start
AcquisitionStart
Starts the acquisition of image data. (WO)
1.00
Beginner
DFNC
Acquisition Stop
AcquisitionStop
Stops the acquisition of image data at the end of the current
line/frame (WO)
1.00
Beginner
DFNC
Acquisition Status
AcquisitionStatus
Indicates whether the camera has been commanded to stop or
to send image data.
1.00
Beginner
DFNC
File Access Control Category
The File Access control in CamExpert allows the user to quickly upload and download of various
data files to/from the connected the camera. The supported data files for the camera include
firmware updates and Flat Field coefficients.
Note: that the communication performance when reading and writing large files can be improved
by stopping image acquisition during the transfer.
Figure 24: File Access Control Panel
Содержание Linea HS Series
Страница 5: ...The Linea HS Monochrome Cameras 5 DECLARATION OF CONFORMITY 73 DOCUMENT REVISION HISTORY 74...
Страница 13: ...The Linea HS Monochrome Cameras 13 Responsivity QE Plots Note values measured using 8 bit 1x gain main array...
Страница 14: ...14 The Linea HS Monochrome Cameras Mechanical Drawings Figure 3 HL FM 08K30H 00 R Mechanical Drawing...
Страница 15: ...The Linea HS Monochrome Cameras 15 Figure 4 HL HM 16K30H 00 R Mechanical Drawing...
Страница 26: ...26 Camera Performance and Features Figure 7 Image with incorrect scan direction...