Camera Performance and Features
41
The camera includes 16 user sets where camera setup information can be saved to and restored
from—either at power up, or dynamically during inspection.
The settings active during the current operation can be saved (and thereby become the user
setting) using the user set save feature.
A previously saved user setting (User Set 1 to 16) or the factory settings can be restored using the
user set selector and user set load features.
Either the factory setting or one of the user settings can be selected as the default setting, by
selecting the set in the user set default selector (Camera Power-up configuration option in the
Power-up configuration dialog accessed from the Camera Information category). The set selected is
selected as the default setting and is the set that is loaded and becomes active when the camera is
reset or powered up.
The relationship between these four settings is illustrated in Figure 16. Relationship between the
Camera Settings:
Figure 16. Relationship between the Camera Settings
Active Settings for Current Operation
Active settings are those settings used while the camera is running and include all unsaved
changes made by GenICam input to the settings.
These active settings are stored in the camera’s
volatile
memory and will be lost and cannot be
restored if the camera resets, is powered down, or loses power during operation.
Factory Setting
Active Setting
By GenIcam Command
1
.
Select a ‘User Set’
2
.
Initiate a ‘User Set Load’
User Setting
By GenIcam Command
1
.
Select a ‘User Set’
2
.
Initiate a ‘User Set Save’
By GenIcam Command
1
.
Select a ‘Factory Set’
2
.
Initiate a ‘User Set Load’
By GenIcam GenIcam Command
1
.
Select ‘Default Set’ as Factory
(
Saves Automatically
)
By GenIcam Command
1
.
Select ‘Default Set’ as Uset Set
#
(
Saves Automatically
)
Power Up
Or Reset
Power Up
Or Reset
GenIcam Input
Содержание Linea HS Series
Страница 5: ...The Linea HS Monochrome Cameras 5 DECLARATION OF CONFORMITY 73 DOCUMENT REVISION HISTORY 74...
Страница 13: ...The Linea HS Monochrome Cameras 13 Responsivity QE Plots Note values measured using 8 bit 1x gain main array...
Страница 14: ...14 The Linea HS Monochrome Cameras Mechanical Drawings Figure 3 HL FM 08K30H 00 R Mechanical Drawing...
Страница 15: ...The Linea HS Monochrome Cameras 15 Figure 4 HL HM 16K30H 00 R Mechanical Drawing...
Страница 26: ...26 Camera Performance and Features Figure 7 Image with incorrect scan direction...
Страница 73: ...Declaration of Conformity 73 Declaration of Conformity...