28
Camera Performance and Features
Spatial Correction
Spatial correction is necessary when using HDR or high full well modes. For single array TDI
operation this functionality is not needed and is disabled.
To achieve a sharp image in the vertical direction when running the camera in HDR mode, it is
important that the lines being used are aligned correctly. Line spatial correction is used to ensure
that these lines align.
Spatial correction is not necessary when using the camera with the main array only.
Second Array
64 rows
5 µm x 5 µm pixel
Main Array
128 rows
5 µm x 5 µm pixel
S
c
a
n
D
ire
c
tio
n
Readout
Readout
175 µm gap equivalent to
35 lines
1
6
3
L
in
e
C
o
rr
e
c
tio
n
Figure 9. Camera Line spacing
The camera ensures the scan direction alignment of the lines by delaying the image data for each
row a set amount of time, as dictated by the scan direction. The camera automatically adjusts the
true spatial correction values depending on direction. Spatial correction is then performed in the
frame grabber based on the time stamps provided by the camera. Note: the frame grabber must
be set to two planes to align the data.
Содержание Linea HS Series
Страница 5: ...The Linea HS Monochrome Cameras 5 DECLARATION OF CONFORMITY 73 DOCUMENT REVISION HISTORY 74...
Страница 13: ...The Linea HS Monochrome Cameras 13 Responsivity QE Plots Note values measured using 8 bit 1x gain main array...
Страница 14: ...14 The Linea HS Monochrome Cameras Mechanical Drawings Figure 3 HL FM 08K30H 00 R Mechanical Drawing...
Страница 15: ...The Linea HS Monochrome Cameras 15 Figure 4 HL HM 16K30H 00 R Mechanical Drawing...
Страница 26: ...26 Camera Performance and Features Figure 7 Image with incorrect scan direction...
Страница 73: ...Declaration of Conformity 73 Declaration of Conformity...