Appendix A: GenICam Commands
55
Display Name
Feature
Description
Device
Version
& View
Peak, Image Filtered
Peak, Image Filtered
A low pass filter is applied to the
average line values before
calculating the coefficients. Use
this algorithm if the calibration
target is not uniformly white or if it
is not possible to defocus the
image. Because of the low pass
filter, this algorithm is not able to
correct pixel-to-pixel variations
and so it is preferable to use the
“Peak” algorithm.
Set Target
Set Target
Calculation of PRNU coefficients
to bring all pixels to the target
value.
Set Target, Image Filtered
Set Target, Image Filtered
A low pass filter is applied to the
average line values before
calculating the coefficients. Use
this algorithm if the calibration
target is not uniformly white or if it
is not possible to defocus the
image. Because of the low pass
filter this algorithm is not able to
correct pixel-to-pixel variations
and so it is preferable to use the
“Target” algorithm.
Flat Field Calibration Target
flatfieldCalibrationTarget
Sets the target value for the
“Calibrate PRNU” feature.
Flat Field Calibration Offset
X
flatfieldCalibrationROIOffsetX
Set the starting point of a region of
interest where a flat field
calibration will be performed
1.00
Beginner
DFNC
Flat Field Calibration Width
flatfieldCalibrationROIWidth
Sets the width of the region of
interest where a flat field
calibration will be performed
1.00
Beginner
DFNC
Calibrate FPN
flatfieldCalibrationFPN
Initiates the FPN calibration
process
1.00
Beginner
DFNC
Row Selector
flatfieldCalibrationColorSelector
Specify which sensor rows to
perform PRNU calibration on, all
or individual colors.
1.00
Beginner
DFNC
Calibrate PRNU
flatfieldCalibrationPRNU
Initiates the Flat Field (PRNU)
calibration process
1.00
Beginner
DFNC
Flat Field Correction Current
Active Set
Factory Set
User set (1 thru 16)
flatfieldCorrectionCurrentActiveSet
Factory Set
User set (1 thru 16)
Selects the User PRNU set to be
saved or loaded.
Factory set can only be loaded.
Only the PRNU values are saved
or loaded which is much faster
than saving or loading the full
Factory or User set.
1.00
Guru
DFNC
Содержание Linea HS Series
Страница 5: ...The Linea HS Monochrome Cameras 5 DECLARATION OF CONFORMITY 73 DOCUMENT REVISION HISTORY 74...
Страница 13: ...The Linea HS Monochrome Cameras 13 Responsivity QE Plots Note values measured using 8 bit 1x gain main array...
Страница 14: ...14 The Linea HS Monochrome Cameras Mechanical Drawings Figure 3 HL FM 08K30H 00 R Mechanical Drawing...
Страница 15: ...The Linea HS Monochrome Cameras 15 Figure 4 HL HM 16K30H 00 R Mechanical Drawing...
Страница 26: ...26 Camera Performance and Features Figure 7 Image with incorrect scan direction...