Linea Lite GigE Series Camera
Technical Specifications
•
123
External Output Details
•
The outputs signals can be used in programmable output mode such as strobe, event
notification, etc.
(see
feature).
•
For the Single-Ended Open Drain outputs, the user supplied Pull-up resistor value should be
between 1K and 10K depending on supply rail. Resistor Wattage should be calculated
accordingly.
•
Outputs are open (disabled) on power-up with the default factory settings.
•
A software reset will not reset the outputs to the open state if the outputs are active.
•
A user setup configured to load on boot will not reset the outputs to the open state if the
outputs are active.
•
The output signals are designed to prevent an output signal glitch on power-up or polarity
reversal.
•
Protection Circuit
–
DC Ratings:
•
Output protected against shorts to ground or other voltages
•
Output maximum voltage of 26V at 10 mA, (60°C)
Preliminary