Linea Lite GigE Series Camera
Operational Reference
•
73
Advanced Processing Control Category
The Linea Lite GigE Advanced Processing controls, as shown by CamExpert, group parameters used
to configure Flat Field calibration.
Advanced Processing Control Feature Descriptions
Display Name
Feature & Values
Description
Standard
& View
lutMode
Sets the enable state of the selected LUT module
(Lookup Table).
Expert
DFNC
Off
Off
Disables the LUT.
Active
Active
Enables the selected LUT module.
LUT Type
lutType
Displays the LUT type of the currently selected Lookup
Table.
Expert
DFNC
User Defined
UserDefined
Uses the user programmable LUT.
Gamma Correction
GammaCorrection
Uses gamma LUT
Gamma Correction
gammaCorrection
Sets the gamma correction factor (i.e. inverse gamma).
The gamma correction is applied as an exponent to the
original pixel value.
(Min: 0.001, Max: 2.0, Increment: 0.001)
Expert
DFNC
LUT Selector
LUTSelector
Selects which LUT to control and adjust features.
Guru
Luminance 1
Luminance1
Luminance 1 is under control
LUT Size
lutSize
Specify the LUT size of the selected LUT (Lookup Table).
Available choices are model dependent.
Guru
DFNC
12 Bits/Pixel
Bpp12
12 bits per pixel
LUT Index
LUTIndex
Selects the index (offset) of the coefficient to access in
the selected LUT.
Guru
Preliminary