DIS-2/M StreamerPro HDD Large UTP
45
Dallmeier electronic
10.3.3
Contact with timer
When Contact with timer is set, recording is triggered in the same way as under the
Contact mode. However, recording will stop after the expiry of a pre-set time - Duration
(sec.) box.
¾
In the Start contact (A) box, select the desired
contact on Contact IN.
¾
If the contact used is an “opener“ (default
condition = contact closed), check the invert
signal checkbox (B).
¾
In the Duration (sec.) box, set the recording
duration in seconds (C).
¾
Click on OK to apply your settings.
10.3.4
Contact start / stop
With the setting Contact start/stop, recording is started with one contact and stopped with
another contact.
NOTE
Start and stop can also be achieved with just one contact.
Depending on the contact (opener or closer), one of the two
signals must be inverted (check the invert signal checkbox).
Recording then runs when the contact is pressed, and stops
again when you release the contact.
¾
In the Start contact box, select the contact for
starting recording.
¾
In the Stop contact box, select the contact for
stopping contact.
¾
Depending on the contact type (“opener“ or
“closer“), activate the appropriate invert signal
checkbox.
¾
Confirm with OK.
Fig. 10-10: Contact with timer tab in the
Recording settings dialog
A
B
C
Fig. 10-11: Contact start/stop tab in the
Recording settings dialog