DIS-2/M StreamerPro HDD Large UTP
32
Dallmeier electronic
All areas in the weekly plan which are shown as light colored are active areas (pre-set).
This means that within this time area all selected messages will be sent to the corresponding
alarm host.
¾
Click on the not active button.
¾
Move the mouse pointer over the top left corner of the desired time area.
¾
If you change the position of the cross hairs whilst holding the mouse
button, a dark square will be opened (see Fig. 9-10).
Dark areas are inactive time areas.
The smallest time unit you can set is 15 minutes.
In the example shown here the time from 02:15 to 02:30 has been marked
as not active. This means that within this time period no messages will be
forwarded to the alarm host.
¾
To undo the marking, click on the active button and trace a square over the inactive
area.
You also can remark certain sections within the inactive area as active by tracing the particular
section.
Active and inactive time areas defined using the above-mentioned method are valid for the
entire year.
¾
If no exceptions are to be made (see the following paragraph), click on OK.
Fig. 9-9:
Alarm hosts calendar function, Week timer tab
Fig. 9-10
Fig. 9-11: Inactive time from Monday to Friday from 7:00
to 17:00