Appendix
104
➢
Connection of an electric lock release or strike
Pass the cables through cable entry grommets (see. diagram of the controller)
Make connections as indicated on the diagram on the next page.
Cable gauges required:
- terminals 1 and 2: 0,75 mm
2
up to 15m/1,5 mm
2
up to 30m
- terminals 3, 4, 5 and 6: 0,22 mm
2
(telephone type cable)
Reconnect the battery and press the “BP” button in the controller.
After 20 seconds, the handsets display indicates the relative information.
The electric lock control is ready-for-operation (See. User guide).
NB:
if a position contact is connected, its change of state will be displayed on the handset after
a maximum of 5 seconds.
Fit the used grommets in their slots on the controllers base.
NB:
in factory default, the door control output is adjusted to last 2 secs. It is possible to adjust
the duration to 5 secs to suit your application:
• Press the entrance 1/entrance 2 key
for more than 5 seconds, the handset emits a
resonant BEEP and the
indicator blinks,
• press the
key to change to 5 secs, the handset emits 2 resonant Beeps.
To revert to 2 secs, use the same procedure but press
instead of
.
➢
Connection of a motorised gate
Pass the cables through cable entry grommets (see. diagram of the controller)
Make connections as indicated in the diagram on next page.
The gauge of cable required is: 0.22 mm
2
(telephone type cable)
Reconnect the battery and activate the gate controller with its usual command (not via the
handset).
After about twenty seconds, the handsets display indicates information related to the motorized
gate. The motorized gate is ready-for-operation (see. User guide).
NB:
if a position contact is connected, its change of state will be displayed on the handset after
a maximum of 5 seconds.
Fit the used grommets in their slots on the controllers base.
4
3
2
1
4
3
2
1
Before making any connections disconnect one of the 4 batteries in the controller
to avoid any risk of short circuit!