Installing the DoorPhone
98
* If connecting a strike or electric 12V lock, the position
contact input of the motorised gate must be connected.
Refer to the Connections chapter in the appendices.
7
8
Connect the 6 wires from
the external caller unit to
terminals 7 to 12.*
7 & 8: Data bus
9: Loudspeaker
10: Microphone
11: +6V
12: 0V
9
Slot the grommets into their
slots and position them to
ensure the weather
resistance of the controller.
Be sure to also fit any
un-pierced grommets.
It is imperative to fit all
cable grommets.
10
Use the screws provided
to hold the connected
cable(s) by tightening
the cable clamps.
11
12
Insert the cover onto
the base and secure
it with the 4 screws.
Cut the cable to the
required length.
Pass the cable through
the cable grommet. Strip
the ends of the wires.
The cable must be completely uncoiled.
!
Ensure correct orientation
of the grommets.
!
Do not remove the cable clamps
from their holder.
!
Push the batteries
into the holder
ensuring good contact
between the + pole of the battery
and the metal clip.
!
Insert the four 1.5 V LR20
batteries supplied. Press
the push button to initialise
the controller.
13
Fully extend
the telescopic
antenna in order
to get optimal radio
range.
!
7 (yellow)
8 (brown)
9 (grey)
10 (green)
11 (pink)
12 (white)
+
+
+
+
7
8
9
10 11 12