109
9.1 On the universal transmitter
9.2 On the control panel
9.3 Changing the battery
To change the battery:
1.
put the control panel in installation mode,
press:
then press:
2.
Open the casing of the universal
transmitter (see § on Opening the
transmitter).
3.
Press the release tab on the lithium battery
pack.
4.
Replace the old lithium battery pack with a
new one.
5.
Put the control panel back in user mode,
press:
The control panel acknowledges
battery,
anti-tamper and radio faults
for both
loop
n° 1
and
loop n° 2
.
• Battery fault:
following a system
command, the control panel voice-signals:
• Anti-tamper fault:
Following a system
command, the control panel voice-signals:
• Radio fault:
following a system command,
the control panel voice-signals:
To check whether the universal transmitter’s
battery is low, press on the test button.
If the test LED indicator lamp does not light
up, the lithium battery pack should be
changed.
LED indicator
lamp
master code
engineer installer
code
engineer installer
code
“Beep, fault, battery, detector X,
beep, fault, battery, remote control X”
“Beep, fault, tamper, detector X,
beep, fault, tamper, remote control X”
“Beep, fault, radio, detector X,
beep, fault, radio, remote control X”
IMPORTANT: the universal transmitter
parameters are saved when the battery is
changed.
9. Maintenance
• The lithium battery pack must be replaced by
the same type of pack with the same technical
characteristics, i.e. (3,6 V - 4 Ah).
• We advise you to use the DAITEM BatLi26
pack available in the catalogue in order to
guarantee individual safety and equipment
reliability.
• Dispose of the waste lithium power
pack in an appropriate recycling bin.