110
10. Technical data
Technical data Universal transmitter
Built-in magnetic contact 1 reed switch type contact
Connection terminal block • terminal block n° 1
for external contact • terminal block n° 2
Maximum number of external 5
contacts per terminal block
Maximum length 10 m
of connection loop
Use indoor
Power supply DAITEM 3.6 V 4 Ah BatLI26 lithium battery pack
Battery life • 4 years (if both loops used)
• 5 years (if only 1 loop used)
Radio links TwinBand
®
:
• 433.050 MHz - 434.790 MHz, 10 mW max,
Duty cycle: 10%
• 868 MHz - 870 MHz, 25 mW max, Duty cycle: 0,1%
Test pushbutton 1 (on front face)
Two-colour LED indicator lamp • red: loop n° 1
• green: loop n° 2
Operating temperature -5°C to +55°C
Anti-tamper protection • against opening
• against removal
• against loop cutting (if anti-tamper external contact
connected)
Degrees of mechanical protection IP 30 / IK 04
Dimensions L x W x H 165 x 35 x 35
Weight 120 g
To obtain advice when installing your system
or before returning equipment, please contact
the Daitem technical support team (see telephone
number at the back of the alarm system
installation manual) or check the web site at:
www.daitem.co.uk
A team of qualified technicians will advise you
what to do.
Hager Security SAS hereby declares that the radioelectric
equipment, reference 221-21X, complies with the
requirements of the following 2014/53/EU RE-D directive.
The full text of the EU Declaration of Conformity is available
at the address: www.daitem.co.uk.
Non-contractual document, may be modified without prior notice.
Содержание 221-21 Series
Страница 111: ...111 ...
Страница 112: ...803427 J Daitem 02 20 www daitem com ...