101
5.4 To be filled in according to the application(s) to be performed
please
complete
Configuration sequence
Application Loop Parameter n° Parameter value
1
n° 1
2
3
4
5
n° 2
6
7
9
LED indicator
lamp OFF
LED indicator
lamp ON
sequence
approx.
5 sec.
approx. 10 sec.
approx.
2 sec.
approx. 10 sec.
To
start
the
sequence press
& hold the key until
the LED indicator
lamp goes out
Press the key
as many
times as the
required
parameter number
Press & hold
the key
until the
LED indicator
lamp temporarily
goes out
Press the key
as many times
as the
required parameter number
.
(*)
Wait one second between
digits
To
end
the
sequence press
& hold the key until
the LED indicator
lamp goes out
LED indicator
lamp remains
ON =
configuration
programmed
1 sec
(
*
)
(
*
)
1
st
digit
2
nd
digit
3
rd
digit
1 sec
IMPORTANT: each loop must be configured.