background image

M

odel

 n

oMenClature

Nomenclature

Note: Text displayed in Bold-Italics designate standard offering.

Category 

Code Item 

Code Option 

Code Designation & Description 

(Bold-Italic = Standard)

Product Category 

01 

=  Water Source Heat Pump

Product Identifier  

02 

2-4 

WXH   =  Slope Top Wall Mtd/High Sill/DDC Less Board/Chassis Only 

 

 

 

WXL  =  Flat Top Wall Mtd/High Sill/DDC Less Board/Chassis Only

 

 

 

WXM  =  Flat Top Wall Mtd/Low Sill/DDC Less Board/Chassis Only

 

 

 

WXN  =  Flat Top Wall Mtd/High Sill/DDC Less Board 

 

 

 

 

WXP  =  Flat Top Wall Mtd/Low Sill/DDC Less Board 

 

 

 

 

WXR  =  Slope Top Wall Mtd/High Sill/DDC Less Board   

 

 

 

 

WXT  =  Slope Top Wall Mtd/Low Sill/DDC Less Board/Chassis Only 

 

 

 

WXV  =  Slope Top Wall Mtd/Low Sill/DDC Less Board 

 

 

 

WZB  =  Flat Top Wall Mtd/Low Sill/Mark IV   

 

 

 

 

WZJ  =  Flat Top Wall Mtd/High Sill/Mark IV   

 

 

 

 

WZN  =  Slope Top Wall Mtd/Low Sill/Mark IV 

 

 

 

WZU  =  Slope Top Wall Mtd/High Sill/Mark IV/Chassis Only 

 

 

 

 

WZV  =  Slope Top Wall Mtd/Low Sill/Mark IV/Chassis Only 

 

 

 

 

WZW  =  Flat Top Wall Mtd/High Sill/Mark IV/Chassis Only 

 

 

 

 

WZX  =  Flat Top Wall Mtd/Low Sill/Mark IV/Chassis Only 

 

 

 

 

WZY  =  Slope Top Wall Mtd/High Sill/Mark IV 

Design Series (Vintage)  

03 

=  Design Series 2

 

 

 

=  Design Series 3

Nominal Capacity  

04 

6-8 

009  =  9,000 Btuh Nominal Cooling

 

  

012  =  12,000 Btuh Nominal Cooling

 

 

 

015  =  15,000 Btuh Nominal Cooling

 

 

 

019  =  19,000 Btuh Nominal Cooling

Voltage  

05 

=  115-60-1 (Size 009 and 012 only)

 

  

E  = 208-230/60/1

 

  

=  265/277-60-1 (Size 009 and 015 only)

Coil Options 

06 

10 

=  Cupro-Nickel Coax Coil, Geothermal

 

 

 S 

=  Copper-Steel Coax Coil 

 

 

 

=  Cupro-Nickel Coax Coil

  

 

 

 

 

=  Copper-Steel Coax, Geothermal

Heating Options 

07 

11-12 

00  = None

(Not available in 115/60/1 voltage) 

 

 

20 

=  1.0 kW Electric Heat Nominal

 

 

 

30 

=  2.0 kW Electric Heat Nominal

 

 

 

 

 Note: See Table 7 on page 14 for allowable maximum kW based on  

 

 

 

 

  voltage selection

Hand Orientation 

08 

13 

U  = Right

 

  

V  = Left 

Controls  

09 

14-15 

11 

=  Unit-Mounted ACO

 

  

12 

=  Unit-Mounted MCO

 

  

13 

=  24V Wall T-Stat Setup

*Note: Code 00 designed for use with 

  

 

25 

=  Unit-Mounted ACO with Low Limit, NSB and Override

field-installed Alerton control board

 

 

 

00 

=  None (DDC Less Control)*

Discharge  

10 

16-17 

AA  = Top

Return Air 

11 

18-19 

13 

=  Front (Low sill only)

 

  

14 

=  Bottom (High sill only)

Power Connection 

12 

20 

=  Std. Electrical Junction Box

 

  

=  Cord (Chassis Only) 

 

 

 

=  Power Cord w/Fused Disconnect  

 

 

 

 

  (Available with cabinet and chassis combination)

Color 13 

21 

=  Putty Beige (Flat-top only) 

 

 

 

=  Cupola White (Slope-top and Flat-top)

 

 

 

=  Soft Gray (Flat-top only)

 

  

=  Antique Ivory (Standard color for slope-top, option for flat-top)

 

 

 

Z  = None

IM 447-11 

www.DaikinApplied.com

Содержание WAA

Страница 1: ...els For Replacement of McQuay Console Models WAA WAF WAG WAH WAS WAX WCB WCQ WDA WDB WDC WDD WDE WDF WDG WDH WDJ WDL WDN WDS WDU WDX WDY WDZ WFQ WLA WLB WLC WLL WLZ WMA WMB WMC WMD WME WMF WMG WMH WMJ...

Страница 2: ......

Страница 3: ...lation 19 Multiple Unit Control Panel for Mark IV 20 Field Installed Outside Air Damper Accessory 21 Manual Outside Air Damper 21 Motorized Outside Air Damper 21 Motorized Outside Air Damper Wiring 22...

Страница 4: ...al Capacity 04 6 8 009 9 000 Btuh Nominal Cooling 012 12 000 Btuh Nominal Cooling 015 15 000 Btuh Nominal Cooling 019 19 000 Btuh Nominal Cooling Voltage 05 9 A 115 60 1 Size 009 and 012 only E 208 23...

Страница 5: ...WMO WMR WMS WMY WMZ WZS WZY 1 Field supplied control board 2 Subbase not included Physical Data Table 1 Physical Data Unit Size 009 012 015 019 Fan Wheel D x W in 5 3 4 x 9 15 5 3 4 x 9 15 6 x 7 8 6...

Страница 6: ...overed upon unpacking make a written request for inspection by the carrier s agent within fifteen 15 days of the delivery date and file a claim with the carrier Pre Installation WARNING The installer...

Страница 7: ...se STOP If an outside air damper kit is to be installed refer to Field Installed Outside Air Damper Acces sory on page 21 for the manual damper or the motorized damper kit and install it now 4 Positio...

Страница 8: ...ve a built in adjustable memory stop to eliminate rebalancing The valve installed on the return line acts as a balancing valve to adjust the proper water flow Each shutoff balancing valve has 1 2 FPT...

Страница 9: ...T 50 43 81 1 08 Condensate Hose Connection Each unit is supplied with a 3 4 19mm I D clear vinyl condensate hose internally trapped within the chassis The hose extends 14 356mm out of the chassis with...

Страница 10: ...itate removal for service Hard piping can also be brought directly to the unit although it is not recommended since additional noise 4 Some flexible hose threaded fittings are supplied with sealant co...

Страница 11: ...ater slightly alkaline pH 7 5 to 8 5 The specified percentage of antifreeze may also be added at this time Use commercial grade antifreeze designed for HVAC systems only Do not use automotive grade an...

Страница 12: ...Junction Box Figure 8 Cord plug connection field installed Power Cord Receptacle Plug Fuse Holder Switch Backwrap Fuse Disconnect Box 10 0 254mm 5 00 127mm Figure 9 Cabinet power connection field inst...

Страница 13: ...nimum the other two conditions may not exceed the normal condition for standard units Extended range unit may combine any two maximum conditions but not more than two with all other conditions being n...

Страница 14: ...A Min Volts Min Circuit Ampacity Max Fuse Size Volt Hz Phase kW Amps RLA LRA Nominal Actual 009 208 60 1 1 0 0 62 3 0 3 7 22 0 40 4 10 197 5 0 15 230 60 1 0 75 3 3 3 7 22 0 40 4 10 197 5 0 15 265 60 1...

Страница 15: ...itch is depressed the fan will run Cooling or Heating Auto Operation Rotate the thermostat knob to either warmer or cooler Select fan speed Depress the start button Unit will start within 0 to 32 seco...

Страница 16: ...ng shown below can only be used when the P terminal is not being used as a pump re start signal to other equipment If the P terminal must be used as a pump restart signal to other equipment then wire...

Страница 17: ...range yellow and white connections are short flying leads pre attached to the board The diagrams shown are some connection examples WSHP Mark IV AC Board Low Voltage Terminal Strip WSHP Mark IV AC Boa...

Страница 18: ...E L U A P V R C W1 Y1 W2 Y2 G Thermostat Terminals C R Non Programmable Auto or Manual Changeover Two Stage Heat Two Stage Cool Night Setback Override Dimensions Specifications Electrical Rating 24 VA...

Страница 19: ...2 Select an appropriate location for mounting the remote sensor 3 Mount remote sensor unit using hardware provided 4 Install two strand shielded wire between remote sensor and thermostat Shielded wir...

Страница 20: ...be used in combination with any other accessories or equipment that require VDC connections to the G W1 or Y1 terminals i e Boilerless System Kit The multiple unit control board provides the componen...

Страница 21: ...er Figure 19 Rear inlet typical motorized damper installation Backwrap Subbase 10 245mm Gasket Table 10 Dimensions in inches mm Unit Type Unit Size A B C Standard Height 009 012 46 1168 45 1143 25 635...

Страница 22: ...wires Damper Assembly Front View of Unit Subbase Chassis Gasket See Note 2 Screws See Note 1 Notes 1 Remove appropriate knock outs and install damper using two 2 8 18 screws provided 2 Install gasket...

Страница 23: ...operate properly perform troubleshooting as needed Troubleshooting Should a major problem develop refer to the following information for possible cause and corrective steps Neither fan nor compressor...

Страница 24: ...erant flow 5 Check for restriction in water flow Insufficient water flow through condenser 1 Check to see that valves are open all the way 2 Check for air in lines 3 Check circulating pump Water drips...

Страница 25: ...stle brush and a vacuum as neccessary 5 Inspect condensate drain lines twice per year and clean as needed to prevent build up lint and other particles that could cause overflow 6 Periodic lockouts alm...

Страница 26: ...ri mary wire and connecting the power lead to the orange transformer primary wire Place an insulation cap on the red transformer primary wire 2 All temperature and pressure switches are normally close...

Страница 27: ...ard 5 Transformer 6 Boilerless Relay 7 Shutdown Relay 8 Auxiliary Relay 9 Heater Relay 10 Water Reg Valve Relay 11 Low Limit Thermostat 12 Night Setback Thermostat 14 Terminal Board 1 15 Terminal Boar...

Страница 28: ...Boilerless Relay 7 Shutdown Relay 8 Auxiliary Relay 9 Heater Relay 10 Water Reg Valve Relay 11 Low Limit Thermostat 12 Night Setback Thermostat 13 Override Switch 14 Terminal Board 1 15 Terminal Boar...

Страница 29: ...sformer 6 Boilerless Relay 7 Shutdown Relay 8 Auxiliary Relay 9 Heater Relay 10 Water Reg Valve Relay 11 Low Limit Thermostat 12 Night Setback Thermostat 13 Override Switch 14 Terminal Board 1 15 Term...

Страница 30: ...lock 4 PC Board 5 Transformer 6 Boilerless Relay 7 Shutdown Relay 8 Auxiliary Relay 9 Heater Relay 10 Water Reg Valve Relay 11 Low Limit Thermostat 12 Night Setback Thermostat 14 Terminal Board 1 15 T...

Страница 31: ...mer 6 Boilerless Relay 7 Shutdown Relay 8 Auxiliary Relay 9 Heater Relay 10 Water Reg Valve Relay 11 Low Limit Thermostat 12 Night Setback Thermostat 13 Override Switch 14 Terminal Board 1 15 Terminal...

Страница 32: ...of Air ____________________________________________________________________ Filters Clean _____________________________________________________________________________ Condensate Traps Installed _____...

Страница 33: ...be converted to GPM by looking in the equipment specificaton catalog Caution P GPM Note A conversion table must be used to find GPM from Delta P measurements Loop Fluid Temperature Rise Drop through...

Страница 34: ...e 2 Model Serial H P EWT 3 LWT 4 EWP 1 LWP 2 EAT 5 LAT 6 Volts Amps Cool ing Check Air Filter and Coil Comments more comments on back 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25...

Страница 35: ...Notes Comments Form WS CTS 00 01 Rev 4 14 www DaikinApplied com 35 IM 447 11...

Страница 36: ...ent Warranty All Daikin equipment is sold pursuant to its standard terms and conditions of sale including To find your local Daikin Applied Representative go to www DaikinApplied com Aftermarket Servi...

Отзывы: