System Configuration
Installation site
To install the air conditioner in the following types of environments, consult the dealer.
•
Places with an oily ambient or where steam or soot occurs.
•
Salty environment such as coastal areas.
•
Places where sulfide gas occurs such as hot springs.
•
Places where snow may block the outdoor unit.
The drain from the outdoor unit must be discharged to a place of good drainage.
Consider nuisance to your neighbours from noises
For installation, choose a place as described below.
•
A place solid enough to bear the weight of the unit which does not amplify the operation noise or
vibration.
•
A place from where the air discharged from the outdoor unit or the operation noise will not
annoy your neighbours.
Electrical work
•
For power supply, be sure to use a separate power circuit dedicated to the air conditioner.
System relocation
•
Relocating the air conditioner requires specialized knowledge and skills. Please consult the
dealer if relocation is necessary for moving or remodeling
•
To avoid oxygen deficiency, ventilate the room sufficiently if equipment with burner is
used together with the air conditioner.
•
Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply
cord.
•
Do not connect the air conditioner to a power supply different from the one as specified. It may
cause trouble or fire.
•
Depending on the environment, an earth leakage breaker must be installed. Lack of an earth
leakage breaker may result in electric shocks.
•
Arrange the drain hose to ensure smooth drainage. Incomplete draining may cause wetting of the
building, furniture etc.
•
Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris
accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals
can cause malfunc-tions, smoke or fire when making contact with electrical parts.
•
Do not operate the air conditioner with wet hands.
•
Do not wash the indoor unit with excessive water, only use a slightly wet cloth.
•
Do not place things such as vessels containing water or anything else on top of the unit.
Water may penetrate into the unit and degrade electrical insulations, resulting in an
electric shock.
Содержание SiEN04-306D
Страница 109: ...Instruction SiEN04 306D 100 System Configuration...
Страница 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure...
Страница 200: ...SiEN04 306D Others 191 Part 8 Others 1 Others 192 1 1 Test Run from the remote control 192 1 2 Jumper Settings 193...
Страница 203: ...Others SiEN04 306D 194 Others...
Страница 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS...
Страница 216: ...SiEN04 306D Wiring Diagrams Appendix 207 RKD18 24 28BVMS...
Страница 217: ...Wiring Diagrams SiEN04 306D 208 Appendix...