SiEN04-306D
Specifications
Specifications
21
50Hz 220V
Note:
MAX. interunit piping length: 30m
MAX. interunit height difference: 20m
Amount of additional charge for piping length exceeding 10m :20g/m(18 class), 50g/m(24·28 class)
The data are based on the conditions shown in the table below.
Model
Indoor Units
FTKD18BVMS
FTKD24BVMS
FTKD28BVMS
Outdoor Units
RKD18BVMS
RKD24BVMS
RKD28BVMS
Capacity
Rated (Min.~Max.)
kW
5.2 (0.9~5.8)
6.1 (0.9~7.0)
7.5 (0.9~7.8)
Btu/h
17,700 (3,070~19,800)
20,800 (3,070~23,900)
25,600 (3,070~26,600)
kcal/h
4,470 (770~4,990)
5,250 (770~6,020)
6,450 (775~6,710)
Moisture Removal
L/h
2.9
3.9
4.5
Running Current (Rated)
A
6.9
8.5
13.7
Power Consumption
Rated (Min.~Max.)
W
1,500 (450~2,300)
1,850 (450~2,900)
2,970 (450~3,270)
Power Factor
%
98.8
98.9
98.5
COP (Rated)
W/W
3.47
3.30
2.53
Piping
Connections
Liquid
mm
φ
6.4
φ
9.5
φ
9.5
Gas
mm
φ
15.9
φ
15.9
φ
15.9
Drain
mm
φ
18.0
φ
18.0
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Indoor Unit
FTKD18BVMS
FTKD24BVMS
FTKD28BVMS
Front Panel Color
White
White
White
Air Flow Rate
m
3
/min
(cfm)
H
17.4 (614)
17.9 (632)
19.0 (671)
M
14.6 (515)
15.0 (530)
15.9 (561)
L
12.2 (431)
12.4 (438)
13.1 (462)
SL
10. 8 (381)
11.0 (388)
11.8 (417)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
Motor Output
W
43
43
43
Speed
Steps
5 Steps, Silent and Auto
5 Steps, Silent and Auto
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Air Filter
Removable/Washable/Mildew Proof
Removable/Washable/Mildew Proof
Removable/Washable/Mildew Proof
Running Current
A
0.21
0.23
0.24
Power Consumption
W
45
50
52
Power Factor
%
97.4
98.8
98.5
Temperature Control
Microcomputer Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×1,050×238
290×1,050×238
290×1,050×238
Packaged Dimensions (H×W×D)
mm
337×1,147×366
337×1,147×366
337×1,147×366
Weight
kg
12
12
12
Gross Weight
kg
17
17
17
Operation
Sound
H/M/L/SL
dBA
45/41/36/33
46/42/37/34
47/43/38/35
Outdoor Unit
RKD18BVMS
RKD24BVMS
RKD28BVMS
Casing Color
Ivory White
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC32UXD
2YC45ZXD
2YC63ZXD
Motor Output
W
1,500
1,900
1,900
Refrigerant Oil
Type
SE50P
SUNISO 4GSD.I.
SUNISO 4GSD.I.
Charge
L
0.65
0.75
0.65
Refrigerant
Type
R22
R22
R22
Charge
kg
1.60
1.70
1.80
Air Flow Rate
m
3
/min (cfm)
H
46.3 (1,634)
51.5 (1,818)
56.0 (1,977)
L
42.9 (1,514)
41.5 (1,465)
44.5 (1,571)
Fan
Type
Propeller
Propeller
Propeller
Motor Output
W
53
53
53
Running Current
A
6.69
8.27
13.46
Power Consumption
W
1,455
1,800
2,918
Power Factor
%
98.9
98.9
98.5
Starting Current
A
6.9
8.5
13.7
Dimensions (H×W×D)
mm
735×825×300
735×825×300
735×825×300
Packaged Dimensions (H×W×D)
mm
784×960×390
784×960×390
784×960×390
Weight
kg
52
54
56
Gross Weight
kg
57
59
61
Operation
Sound
H/L
dBA
49/46
52/49
52/49
Drawing No.
3D040821
3D040822
3D042234
Conversion Formula
kcal/h=kW×860
Btu/h=kW×3414
cfm=m
3
/min×35.3
Cooling
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
7.5m
Содержание SiEN04-306D
Страница 109: ...Instruction SiEN04 306D 100 System Configuration...
Страница 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure...
Страница 200: ...SiEN04 306D Others 191 Part 8 Others 1 Others 192 1 1 Test Run from the remote control 192 1 2 Jumper Settings 193...
Страница 203: ...Others SiEN04 306D 194 Others...
Страница 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS...
Страница 216: ...SiEN04 306D Wiring Diagrams Appendix 207 RKD18 24 28BVMS...
Страница 217: ...Wiring Diagrams SiEN04 306D 208 Appendix...