Indoor Unit
SiEN04-306D
148
Removal Procedure
1. Indoor Unit
1.1
Removal of the Air Filter / Front Panel
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Features
When the signal receiver
catches a signal from the
remote control, it produces
beep sound and the
operation lamp blinks.
2. Remove the air filters.
1
Hold the front panel by
the tabs on the both
sides and lift it until it
stops with a click.
2
Lift an air filter upwards
slightly by the center
knob, and then pull it
out downwards.
(R2746)
Room temper
a
t
u
re
s
en
s
or
(thermi
s
tor)
(R2747)
Timer l
a
mp
ON/OFF
s
witch
Oper
a
tion l
a
mp
S
ign
a
l
receiver
(R274
8
)
Front p
a
nel
Air filter
(R2749)
Содержание SiEN04-306D
Страница 109: ...Instruction SiEN04 306D 100 System Configuration...
Страница 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure...
Страница 200: ...SiEN04 306D Others 191 Part 8 Others 1 Others 192 1 1 Test Run from the remote control 192 1 2 Jumper Settings 193...
Страница 203: ...Others SiEN04 306D 194 Others...
Страница 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS...
Страница 216: ...SiEN04 306D Wiring Diagrams Appendix 207 RKD18 24 28BVMS...
Страница 217: ...Wiring Diagrams SiEN04 306D 208 Appendix...