Specifications
SiEN04-306D
24
Specifications
50Hz 230V
Note:
MAX. interunit piping length: 30m
MIN. interunit piping length: 1.5m
MAX. interunit height difference: 20m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Model
Indoor Units
FTXS50BVMB
FTXS60BVMB
Outdoor Units
RXS50B(2)VMB
RXS60B(2)VMB
Cooling
Heating
Cooling
Heating
Capacity
Rated (Min.~Max.)
kW
5.0 (0.9~5.8)
5.8 (0.9~7.5)
6.0 (0.9~6.7)
7.0 (0.9~8.0)
Btu/h
17,070 (3,070~19,800)
19,800 (3,070~25,610)
20,480 (3,070~22,870)
23,900 (3,070~27,310)
kcal/h
4,300 (770~4,990)
4,990 (770~6,450)
5,160 (770~5,760)
6,020 (770~6,880)
Moisture Removal
L/h
2.9
—
3.9
—
Running Current (Rated)
A
7.3
7.5
9.3
9.2
Power Consumption
Rated (Min.~Max.)
W
1,660 (450~2,300)
1,700 (450~2,580)
2,120 (450~2,450)
2,090 (450~3,100)
Power Factor
%
98.9
98.6
99.1
98.8
COP
W/W
3.01
3.41
2.83
3.35
Piping
Connections
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
12.7
Drain
mm
φ
18.0
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Indoor Unit
FTXS50BVMB
FTXS60BVMB
Front Panel Color
White
White
Air Flow Rate
m
3
/min
(cfm)
H
11.4 (402)
12.6 (445)
16.2 (572)
17.4 (614)
M
9.7 (342)
10.8 (381)
13.6 (480)
15.1 (533)
L
8.0 (282)
8.9 (314)
11.4 (402)
12.7 (448)
SL
7.1 (251)
7.7 (272)
10.2 (360)
11.4 (402)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
40
43
Speed
Steps
5 Steps, Silent and Auto
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.18
0.20
0.18
0.20
Power Consumption (Rated)
W
40
45
40
45
Power Factor
%
96.6
97.8
96.6
97.8
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×795×238
290×1,050×238
Packaged Dimensions (H×W×D)
mm
280×840×338
337×1,147×366
Weight
kg
9
12
Gross Weight
kg
13
17
Operation
Sound
H/M/L/SL
dBA
44/40/35/32
42/38/33/30
45/41/36/33
44/40/35/32
Sound Power
H
dBA
63
60
63
62
Outdoor Unit
RXS50B(2)VMB
RXS60B(2)VMB
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC32HXD
2YC32HXD
Motor Output
W
1,500
1,500
Refrigerant
Oil
Model
FVC50K
FVC50K
Charge
L
0.65
0.65
Refrigerant
Model
R-410A
R-410A
Charge
kg
1.20
1.70
Air Flow Rate
m
3
/min (cfm)
H
47.7(1,684)
44.1(1,557)
47.6(1,680)
45.5(1,606)
L
44.1(1,557)
44.1(1,557)
44.1(1,557)
45.5(1,606)
Fan
Type
Propeller
Propeller
Motor Output
W
53
53
Running Current (Rated)
A
6.82
7.30
9.12
9.00
Power Consumption (Rated)
W
1,620
1,655
2,080
2,045
Power Factor
%
99.0
98.6
99.2
98.8
Starting Current
A
7.5
9.3
Dimensions (H×W×D)
mm
735×825×300
735×825×300
Packaged Dimensions (H×W×D)
mm
784×960×390
784×960×390
Weight
kg
49
53
Gross Weight
kg
53
57
Operation
Sound
H
dBA
47
48
49
49
Sound Power
H
dBA
63
64
64
64
Drawing No.
3D040778A
3D040779
Conversion Formula
kcal/h=kW×860
Btu/h=kW×3414
cfm=m
3
/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
Содержание SiEN04-306D
Страница 109: ...Instruction SiEN04 306D 100 System Configuration...
Страница 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure...
Страница 200: ...SiEN04 306D Others 191 Part 8 Others 1 Others 192 1 1 Test Run from the remote control 192 1 2 Jumper Settings 193...
Страница 203: ...Others SiEN04 306D 194 Others...
Страница 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS...
Страница 216: ...SiEN04 306D Wiring Diagrams Appendix 207 RKD18 24 28BVMS...
Страница 217: ...Wiring Diagrams SiEN04 306D 208 Appendix...