SiEN04-306D
Indoor Unit
Removal Procedure
163
2
Release the claws on
the left side.
3
Push the fixing claws
on the right side and
release.
4
Pull the heat exchanger
to the front side and
undo the claws
completely, and then lift
it.
Caution
When removing or
reinstalling heat exchanger,
be sure to wear protective
gloves or wrap the heat
exchanger with cloths. (Fins
can cut fingers.)
Step
Procedure
Points
Cl
a
w
s
(R2
8
00)
Cl
a
w
s
(R2
8
01)
He
a
t exch
a
nger
(R2
8
02)