SiEN04-306D
Troubleshooting
Service Diagnosis
109
4.3
Freeze-up Protection Control or High Pressure Control
remote control
Display
A5
Method of
Malfunction
Detection
High pressure control (heat pump model only)
During heating operations, the temperature detected by the indoor heat exchanger
thermistor is used for the high pressure control (stop, outdoor fan stop, etc.)
The freeze-up protection control (operation halt) is activated during cooling operation
according to the temperature detected by the indoor unit heat exchanger thermistor.
Malfunction
Decision
Conditions
High pressure control
During heating operations, the temperature detected by the indoor heat exchanger
thermistor is above 65°C
Freeze-up protection
When the indoor unit heat exchanger temperature is below 0°C during cooling operation.
Supposed
Causes
Operation halt due to clogged air filter of the indoor unit.
Operation halt due to dust accumulation on the indoor unit heat exchanger.
Operation halt due to short-circuit.
Detection error due to faulty indoor unit heat exchanger thermistor.
Detection error due to faulty indoor unit PCB.
Содержание SiEN04-306D
Страница 109: ...Instruction SiEN04 306D 100 System Configuration...
Страница 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure...
Страница 200: ...SiEN04 306D Others 191 Part 8 Others 1 Others 192 1 1 Test Run from the remote control 192 1 2 Jumper Settings 193...
Страница 203: ...Others SiEN04 306D 194 Others...
Страница 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS...
Страница 216: ...SiEN04 306D Wiring Diagrams Appendix 207 RKD18 24 28BVMS...
Страница 217: ...Wiring Diagrams SiEN04 306D 208 Appendix...