SiE33-003
Product Outline
General Information
3
1.2
Outline of New Series Products
In addition to the use of a new refrigerant (R-407C), the new series products incorporate a function-unit-less structure
for significantly improved flexibility and ease of installation.
System outline
No function unit
All models combine master units and slave units or master units, slave units and Plus units.
All models use a new refrigerant with low ozone destruction potential and global warming potential to
minimize environmental loads (see Feature (1)).
With a value of 1 given to the ozone destruction potential and global warming potential of the R11
refrigerant, smaller values mean less environmental impact.
Feature (1)
Use of new refrigerant (R-407C) that does not deplete the ozone layer
Reduction of refrigerant charge volume (approx. 75% as compared to R22-refrigerant unit with 20 HP
and 5-m pipe)
--- Mainly by elimination of function units, simplification of refrigerant circuits and reduction of internal
volume.
< Global warming potential >
Water vapor and carbon gas allow solar rays to pass through, but they hinder the penetration of heat rays
from the surface of the earth. Methane, chlorofluorocarbons and dinitrogen monoxide have similar
characteristics. When the amounts of these gases in the atmosphere increase, heat that normally escapes
through the atmosphere remains near the earth's surface, thus increasing the temperature of air. The
degree of the effect to the earth caused by the atmospheric temperature rise due to these gases is
numerically expressed by global warming potential (GWP).
Feature (2)
Dramatically improved flexibility and ease of field installation by function-unit-less structure
--- Simpler piping work at installation sites
--- Reduced unit installation area
Refrigerant
Condensing
pressure
(MPa)
Capacity
∗
1
COP
Ozone
destruction
potential
Global
warming
potential
R22
Single-component
1.88
100
100
0.05
0.43
R-407C
Non-azeotropic
2.05
98
90~97
0
0.38
∗
1 Capacity value based on theoretical refrigerating cycle
Standard series
General name
Master unit name
Slave unit name
RSXYP~KJY1
RXYP~KJY1
RXEP8·10KJY1
Master
units
Slave
units
(V0800)
B
Master unit
Slave unit
Unit-less system
Conventional system
Previous VRV PLUS
New VRV PLUS
30HP
Function unit
Inverter unit
Constant-speed unit
30HP
Type-D inverter compressor
(10 HP)
Type-D constant-speed
compressor
Type B inverter compressor
(with oil discharge mechanism)
Type-B constant-speed compressor
(with oil discharge mechanism)
(V0802)
Si33-003.book Page 3 Monday, June 25, 2001 9:06 AM
Все каталоги и инструкции здесь:
http
:
//splitoff.ru/tehn-doc.html