To install the swing flap motor
1
Install the coupling piece on the swing flap motor. Install the spring to fix the
coupling piece.
2
Connect the wiring harness to the swing flap motor.
3
Install the swing flap motor in the correct location on the indoor unit.
c
d
a
b
b
a
Swing flap
b
Screw (swing flap motor fixation)
c
Swing flap motor
d
Coupling piece
4
Install and tighten the 2 screws to fix the swing flap motor.
5
Install the swing flap.
6
151].
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.
To remove the swing flap motor wiring harness
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
151].
1
Remove the switch box, see
2
Disconnect the wiring harness from the swing flap motor.
3
Remove the swing flap motor wiring harness from the indoor unit.
4
To install the swing flap motor wiring harness, see
To install the swing flap motor wiring harness
1
Connect the wiring harness connector to the swing flap motor.
2
151].
Is the problem solved?
Action
Yes
No further actions required.