3
|
Components
Service manual
93
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a
A
A
Class 20~42 unit
a
Indoor unit fan motor cover
a
A
A
Class 50~71 unit
a
Indoor unit fan motor cover
3
Remove the rubber from the indoor unit.
4
Remove the indoor unit fan motor from the indoor unit.
5
To install the indoor unit fan motor, see
92].
To install the DC fan motor assembly
1
Install the indoor unit fan motor in its correct location on the fan.
2
Install the rubber in front of the fan motor.
3
Click the indoor unit fan motor cover on the indoor unit. If removed, install
and tighten the screw on the right hand side of the fan motor cover.
Содержание Perfera ARXM R Series