3
|
Components
Service manual
100
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
c
Hook
d
Screw (fan motor cover)
e
Fan motor cover
f
Wiring harness retainer
4
Route the DC fan motor wiring harness through the hooks and install the
harness retainer. Make sure the wiring harness is also routed through the
hooks located behind the harness retainer.
5
Lock the ferrite core on the DC fan motor wiring harness.
6
Install a new tie strap to fix the ferrite core to the indoor unit.
7
Install the turbo fan assembly, see
To install the turbo fan assembly
1
Install the turbo fan assembly on the DC fan motor assembly.
CAUTION
Do NOT install a damaged turbo fan assembly.
2
Install and tighten the nut to fix the turbo fan assembly.
a
a
a
b
c
a
d
a
Screw (bellmouth)
b
Bellmouth
c
Nut (turbo fan assy)
d
Turbo fan assy
3
Install the bellmouth in the correct location on the indoor unit. Install and
tighten the 4 screws to fix the bellmouth.
4
Slowly rotate the turbo fan and check that it does NOT touch the bellmouth.
Repair as needed.
5
Install the indoor unit heat exchanger on the 2 hooks on the right side.
Содержание Perfera ARXM R Series
Страница 1: ...Service manual Split New Perfera R32 RXM20 71R ARXM25 71R FTXM20 71R ATXM25 50R FVXM25 50A...
Страница 254: ......
Страница 255: ......
Страница 256: ...ESIE20 11 2021 01 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...