162
FTXM-V Series EDUS042101
3P124623-1E
12
3.
Select the desired timer number by
pressing the “TIMER NO.” button.
Once the desired timer number is
displayed,
press the “SET”
button.
The display for timer number 2
will stop blinking.
The “
” display will disappear
after 3 seconds.
Select “ ” in the timer number when you do not
wish to set a timer number.
It is possible to set only one timer number.
(The times for turning the unit(s) on and off twice a
day can be set with a single timer number.)
• Timer Number Setting
Group control: select the unit in the individual
screen and set the timer number.
Batch control: set the timer numbers for all con-
nected units.
Zone control: set the timer numbers for all
zone-registered units.
Call up the zones which you wish
to set in the zone screen and set
the timer numbers.
• Since the timer number will be set to after-
press priority, the timer number in the last
screen set will be valid for the connected
units.
Example 1
Setting timer number 1 for unit 1-00 to “1” and
timer number 2 to “2” in the individual screen and
then setting timer number 1 to “3” and timer
number 2 to “4” in the batch screen causes the
timer numbers for all units to be set, so timer
number 1 for unit 1-00 will be “3” and timer num-
ber 2 will be “4”.
Example 2
To prevent leaving units on, timer number 1 is
set to “5” in the batch screen.
Setting timer number 1 in zone number 1 to “ ”
in the zone screen after that will change the
timer number for zone number 1, so the setting
to prevent leaving the units on will be lost for
zone number 1 only.
If a timer number is set incorrectly by accident,
redo the setting in the desired screen.
• What happens when the timer number on
time and off time are set to the same time
When the on time and off time are set to the
same time for the same timer number, operation
does not change.
When the on time and off time are set to the
same time for different timer numbers, the off
time is given priority.
When using timer operation, make sure the
times do not overlap when setting the program of
the schedule timer.
Setting the Operation Code (Fig. 11)
[Registration]
1.
Pressing the “CONTROL MODE”
button causes the currently set operation
code to blink.
Call up the desired code number by pressing the
“CONTROL MODE” button.
Scroll through the code numbers.
2.
Once the code number is displayed,
press the “SET” button.
The display will stop blinking.
The operation code display will disappear after
3 seconds.
[The Operation Code Setting]
Group control: select the unit in the individual screen
and set the operation code.
Batch control: set the operation code for all con-
nected units.
Zone control: set the operation code for all zone-reg-
istered units.
Call up the zones which you wish to set
in the zone screen and set the opera-
tion code.
Since the operation code will be set for after-press pri-
ority, setting the operation code in the zone and individ-
ual screens after setting the operation code in the
batch screen, will cause the operation codes set after-
wards to be valid.
No.
Содержание FTXM09VVJU
Страница 1: ...Heat Pump Split Type Air Conditioners FTXM V Series EDUS042101...
Страница 2: ......
Страница 9: ...FTXM V Series EDUS042101 7 C 3D129693 FTXM18VVJU C 3D129692 FTXM09 12VVJU 4 1 Indoor Unit 4 Dimensions...
Страница 10: ...8 FTXM V Series EDUS042101 C 3D129694 FTXM24VVJU...
Страница 11: ...FTXM V Series EDUS042101 9 3D123362 RXM18VVJU 3D131944B RXM09 12VVJU 4 2 Outdoor Unit...
Страница 12: ...10 FTXM V Series EDUS042101 3D107983A RXM24VVJU...
Страница 14: ...12 FTXM V Series EDUS042101 C 3D129644B RXM18 24VVJU C 3D129643B RXM09 12VVJU 5 2 Outdoor Unit...
Страница 16: ...14 FTXM V Series EDUS042101 3D132216 RXM18VVJU 3D131979 RXM09 12VVJU 6 2 Outdoor Unit...
Страница 17: ...FTXM V Series EDUS042101 15 3D132217 RXM24VVJU...
Страница 28: ...26 FTXM V Series EDUS042101 3D133582A 8 Operation Limit...
Страница 30: ...28 FTXM V Series EDUS042101 C 3D133575 FTXM12VVJU C 3D133574 FTXM09VVJU 9 2 Indoor Unit...
Страница 31: ...FTXM V Series EDUS042101 29 C 3D133577 FTXM24VVJU C 3D133576 FTXM18VVJU...
Страница 32: ...30 FTXM V Series EDUS042101 C 3D133581 RXM12VVJU C 3D133580 RXM09VVJU 9 3 Outdoor Unit...
Страница 33: ...FTXM V Series EDUS042101 31 C 3D133618 RXM24VVJU C 3D133617 RXM18VVJU...
Страница 117: ...FTXM V Series EDUS042101 115 C 3P628774 1 Quick Reference...
Страница 148: ...146 FTXM V Series EDUS042101 1P124687 1A 13 6 DCS302C71 Central Remote Controller Installation Manual...
Страница 149: ...FTXM V Series EDUS042101 147 1P124687 1A...
Страница 150: ...148 FTXM V Series EDUS042101 1P124687 1A...
Страница 151: ...FTXM V Series EDUS042101 149 1P124687 1A...
Страница 152: ...150 FTXM V Series EDUS042101 1P124687 1A...
Страница 156: ...154 FTXM V Series EDUS042101 3P124623 1E 4 Fig 6 Fig 5 Fig 8 Fig 7...
Страница 167: ...FTXM V Series EDUS042101 165 3P124623 1E 15...
Страница 177: ...FTXM V Series EDUS042101 175 3P124623 1E 25 Fig 9 Fig 12 Fig 10 Fig 11...
Страница 178: ...176 FTXM V Series EDUS042101 3P124623 1E 26 Fig 14 Fig 13 Fig 16 Fig 15...
Страница 179: ...FTXM V Series EDUS042101 177 1P126474 1B 13 8 DCS301C71 Unified ON OFF Controller Installation Manual...
Страница 180: ...178 FTXM V Series EDUS042101 1P126474 1B...
Страница 181: ...FTXM V Series EDUS042101 179 1P126474 1B...
Страница 182: ...180 FTXM V Series EDUS042101 1P126474 1B...
Страница 183: ...FTXM V Series EDUS042101 181 1P126474 1B...
Страница 187: ...FTXM V Series EDUS042101 185 3P162015 1A 13 11 DST301BA61 Schedule Timer Controller Installation Manual...
Страница 188: ...186 FTXM V Series EDUS042101 3P162015 1A...
Страница 189: ...FTXM V Series EDUS042101 187 3P162015 1A...
Страница 190: ...188 FTXM V Series EDUS042101 3P162015 1A...
Страница 191: ...FTXM V Series EDUS042101 189 3P162015 1A...
Страница 207: ...FTXM V Series EDUS042101 205 3P534932 1D 13 14 KPW063B4 Air Direction Adjustment Grille...
Страница 208: ...206 FTXM V Series EDUS042101 3P534932 1D...
Страница 209: ...FTXM V Series EDUS042101 207 2P403095 1 13 15 KKG063A42 Back Protection Wire Net...
Страница 229: ...FTXM V Series EDUS042101 227 3P436071 1 13 21 KPS063A41 Snow Hood Intake Side Plate...
Страница 230: ...228 FTXM V Series EDUS042101 3P436071 1...
Страница 231: ...FTXM V Series EDUS042101 229 3P436072 1 13 22 KPS063A44 Snow Hood Intake Rear Plate...
Страница 232: ...230 FTXM V Series EDUS042101 3P436072 1...
Страница 233: ...FTXM V Series EDUS042101 231 3P436073 1 13 23 KPS063A47 Snow Hood Outlet...
Страница 234: ...232 FTXM V Series EDUS042101 3P436073 1...
Страница 235: ......