2.1
System Operation
2.1.1
Heating Mode
Heat pump only
operation
The heat pump and pump are enabled, the gas boiler is bypassed.
Space heating is enabled.
Allowable outdoor temperature range: -25 to 25°C.
a
Outdoor unit
b
Indoor unit
c
Plate heat exchanger
d
Gas boiler
e
3-way valve
RADIATOR
PUMP
b
d
e
c
a