5
|
About the units and options
Installer reference guide
28
EPRA08~W1 + ETVH/9W
Daikin Altherma 3 H MT F
4P634886-1 – 2021.03
5.2.2 Identification label: Indoor unit
Location
Model identification
Example:
E TV H 12 S 23 EA 6V
Code
Description
E
European model
TV
Floor-standing hydro-split unit with integrated tank
H
H=Heating only
X=Heating/cooling
12
Capacity class
S
Integrated tank material: Stainless steel
23
Integrated tank volume
EA
Model series
6V
Backup heater model
5.3 Combining units and options
INFORMATION
Certain options may NOT be available in your country.
5.3.1 Possible combinations of indoor unit and outdoor unit
Indoor unit
Outdoor unit
EPRA08
EPRA10
EPRA12
ETVH/X12
O
O
O
5.3.2 Possible options for the outdoor unit
Mounting stand (EKMST1, EKMST2)
In colder regions where heavy snowfall can occur, it is recommended to install the
outdoor unit on a mounting frame. Use one of the following models:
▪
EKMST1 with flange feet: to install the outdoor unit on a concrete foundation
where drilling is allowed.
▪
EKMST2 with rubber feet: to install the outdoor unit on foundations where
drilling is not allowed or possible, such as flat roofs or pavements.
For installation instructions, see the installation manual of the mounting stand.