14
|
Troubleshooting
Installer reference guide
250
EPRA08~W1 + ETVH/9W
Daikin Altherma 3 H MT F
4P634886-1 – 2021.03
Error code
Description
8F-00
Abnormal increase outlet water temperature
(DHW)
8H-00
Abnormal increase outlet water temperature
8H-01
Overheating mixed water circuit
8H-02
Overheating mixed water circuit (thermostat)
8H-03
Overheating water circuit (thermostat)
A1-00
Zero cross detection problem
A5-00
OU: High pressure peak cut / freeze protection
problem
AA-01
Backup heater overheated or BUH power cable
not connected
AC-00
Booster heater overheated
AH-00
Tank disinfection function not completed
correctly
AJ-03
Too long DHW heat-up time required
C0-00
Flow sensor malfunction
C0-01
Flow switch malfunction
C0-02
Flow switch malfunction
C4-00
Heat exchanger temperature sensor problem
C5-00
Heat exchanger thermistor abnormality
CJ-02
Room temperature sensor problem
E1-00
OU: PCB defect
E2-00
Leakage current detection error
E3-00
OU: Actuation of high pressure switch (HPS)
E3-24
High pressure switch abnormality
E4-00
Abnormal suction pressure
E5-00
OU: Overheat of inverter compressor motor
E6-00
OU: Compressor startup defect
E7-00
OU: Malfunction of outdoor unit fan motor
E8-00
OU: Power input overvoltage
E9-00
Malfunction of electronic expansion valve
EA-00
OU: Cool/heat switchover problem
EA-01
4WV switching error
EC-00
Abnormal increase tank temperature
EC-04
Tank preheating
Содержание EPRA08EAV3
Страница 289: ...13 13...
Страница 290: ......
Страница 291: ......
Страница 292: ...4P634886 1 2021 03 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...