【INSTRUCTION MANUAL】
DAIKIN INDUSTRIES, LTD
.
SE-04430
Att.13
[Attached document B]
Caution
・
In case of an alarm occurs, treat it as mentioned in this instruction manual.
・
Make contact to our Service Division when an alarm isn’t dissolved even if you take measures.
Holding function of pressure switch indication.
1) It works only when choosing pressure switch indication holding with the pressure switch.
2) If the setup of the pressure switch is lower and passes beyond the delay time, pressure alarm
is outputted, and then pressure alarm indicates “E63”.
3) Though pressure alarm is canceled, if pressure reverts above the setup of the pressure switch,
“E63” is kept to indicate until “ENT KEY”
is pushed. (It is also cleared with resetting power supply.)
4-2 After the retrial, when alarm output.
Pressure
Mode
Alarm
Indication
H: Condition without alarm
L: Alarm condition
Normal control
Occurrence of
defective starting
Pressure decline time
Max. 10 seconds
Defective start condition
Retrial (positioning)
Actual
pressure
indication
※
If E80 is outputted, it is enable to be canceled except for resetting power supply.
※
Even if turn on power supply again , it may not work normally.
(There is the possibility of the damage of the controller or the motor pump.)
Pressure
switch acts
Pressure
Internal mode
Alarm
Indication
Entry key input
Pressure switch
setup
H: Condition without alarm
L: Alarm condition
Pressure switch
delay time
Normal control
Actual pressure indication
Normal control
Actual pressure
indication