【INSTRUCTION MANUAL】
DAIKIN INDUSTRIES, LTD
.
SE-04430
Att.12
[Attached document B]
2. Alarm of pressure decline (Only when a pressure switch function is set up.)
Pressure
Mode
Alarm
Indication
Alarm count
Pressure switch
setup
Pressure switch
delay time
Under 30
seconds
30 seconds
Normal control
Actual pressure indication
Actual
pressure
indication
Normal control
Pressure decline
condition
L: Alarm condition
H: Condition
without alarm
3. Alarm that motor temperature abnormally raises.
※
If E41 is outputted, it is enable to be canceled except for resetting power supply.
※
Alarm has been outputted soon, in case the temperature is more than 105
℃
at starting the power supply.
105
℃
Motor
temperature
Mode
Alarm
Indication
Alarm count
L: Alarm condition
H: Condition without alarm
Normal control
Motor stop
High temperature
abnormal condition
Actual pressure indication
10 minutes
1 minute
4.Defective starting alarm
1.3
~
6.5 seconds
4-1 When a retrial reverts.
※
2
※
2. At using of a pressure switch, alarm may be outputted as well as
※
1 of 1-2).
Pressure
Mode
Alarm
Indication
H: Condition without alarm
Actual pressure indication
Actual
pressure
indication
Normal control
Normal control
Retrial (positioning)
Pressure decline time
Occurrence of
defective starting