【INSTRUCTION MANUAL】
DAIKIN INDUSTRIES, LTD
.
SE-04430
Att.8
[Attached document
A
]
Adjustment screw & lock nut of
flow control valve for
minimum number of revolutions
Caution
・
In case of loosening too much adjustment screw of flow control valve, it comes off the valve block.
・
When PC setup pressure is set less than 6 Mpa, remove the fixed flow control plug,
In case of installing the fixed flow control plug, the number of revolutions don’t increase.
An operation example is shown
.
<
Example
>
In case of adjusting the minimum number of revolutions to 350 min
-1
Rotate adjustment screw of
flow control valve to
clockwise
Set up adjustment screw
Change to monitor mode
Indication number of revolutions
Operation process
Key operation
3-digit LED
Remarks
n05
:
number
of revolutions
Monitor mode
Change to monitor mode
×
10
600min
-1
:
example
(
Actual number of
revolutions
)
Or
min
-1
Return to actual pressure
indication