PIM00411
12-5
Please confirm the the mode code of your product.
■
Table 1: Different default parameter values for different products
Product Type
Item
Name
EHU15R-M0701-30
EHU15R-M0702-30
EHU30R-M0701-30
EHU30R-M0702-30
P10
Response gain
25
20
■
Table 2: PQ setting list
Product Type
Name
EHU15R-M0701-30
EHU15R-M0702-30
EHU30R-M0701-30
EHU30R-M0702-30
The default value
0.5
Range
[MPa]
0.5
~
7.0
The default value
7
Pressure
setting
Range
[×10PSI]
7
~
101
The default value
15.2
28.5
Flow rate
setting
Range
[L/min]
2.5
~
15.2
3.5
~
28.5
The default value
0.1
Acceleration
time setting
Range
[sec/MPa]
[sec/1000min
-1
]
0.01
~
99.99
The default value
0.1
Deceleration
time setting
Range
[sec/MPa]
[sec/1000min
-1
]
0.01
~
99.99
CAUTION
The standard factory setting of "P04: Pressure unit select setting" is MPa.
When it was changed to PSI display, please adhere a seal to make it understand easy. Please prepare the display
seal. However, If it is used in Japan, you will be punished by the Measurement Law.
12.2
[P00: DI_A] Valid logic switch of the start-stop signal
You can make the motor start / stop by the input signal of the digital input terminal DIN1.
This parameter allows you to switch the effective logic of the digital input terminal DIN1.
No.
Sign
Name
Setting Range
Factory Settings
Unit
P00
DI_A
Start-stop signal
switch
0: Pump starts to run when the DIN1 is ON
1: Pump starts to run when the DIN1 is OFF
1
-
DIN1 Terminal State
Settings
OFF
ON
0
Pump stop
Pump start
1
Pump start
Pump stop
CAUTION
Frequently turning ON / OFF the power supply may damage the controller.
Please turn ON / OFF the pump by the digital input terminal DIN1 except in an emergency.
Note
If it is used without a start-stop signal, by setting the value as "1", the hydraulic unit will start
automatically at power-on.