PIM00411
12-4
Item
Sign
Name
Operating range
Default
setting
Description
Reference
P34 E_TM
Motor start-up
abnormality
judgment time
0.01
~
9.99[sec]
2
Setting the judgment time of the alarm
“E31: Motor start-up abnormality”.
-
0.00
~
2.00[MPa]
0.5
P35 DR_L
Dry running
judgment pressure 0
~
290[PSI]
7.2
Setting the pressure conditions to
determine the alarm “E64: Dry running
abnormality”.
-
P36 DR_T
Dry running
judgment time
0.01
~
9.99[sec]
3
Setting the time of determining the alarm
“E64: Dry running abnormality”.
-
P37 SM_R
Unused setting
items
-
-
It does not affect the function, but please
do not change the setting.
-
0.00
~
1.00[MPa]
0.5
P38
P_DF
Pressure switch
output dead zone 0
~
145[×10 PSI]
7.2
Setting the pressure threshold value for
determining the pressure return, after the
pressure switch being actuated.
Setting by the difference of the positive
direction for:" P01: pressure switch".
12-10
P39 DO_S
Digital output
selection
0
~
7
0
Setting the function of the signal to be
output from the digital output DO1.
0: PQ number switching completion
output
1: Motor running output
2: High-pressure side operation output
3: Temperature rise during operation
4: Pressure and flow rate coincidence
output
5: Pressure coincidence output
6: Flow rate coincidence output
7: Fully charged
12-8
P40
PL_D
Unused setting
items
-
-
It does not affect the function, but please
do not change the setting.
-
P41 PCMW
Pressure
coincidence
detection range
0
~
99
[
%
]
5
Setting the pressure coincidence
detection range.
When the "P39: Digital output selection"
is "4,5", it will be valid.
12-8
P42 PCMM
The minimum
value of pressure
coincidence
detection
0
~
99.9
[MPa]
0.1
Setting the minimum pressure of the
pressure coincidence detection.
When the "P39: Digital output selection"
is "4,5", it will be valid.
12-8
P43 QCMW
Flow rate
coincidence
detection range
0
~
99
[
%
]
5
Setting the flow rate coincidence
detection range.
When the "P39: Digital output selection"
is "4,6", it will be valid.
12-8
P44 QCMM
The minimum
value
of flow
rate coincidence
detection
0
~
99.9
[L/min]
0.2
Setting the the minimum value of flow
rate coincidence detection.
When the "P39: Digital output selection"
is "4,6", it will be valid.
12-8
P45 AC_F
AC fan motor
synchronization
0: Always
operation
1: Synchronized
operation
0
DIN1: It can start / stop the AC fan in
synchronization with the start / stop
signal.
12-14