PIM00411
13-2
Alarm
Code
Name
Reason
Countermeasure
Failure of the encoder
・
Replace the motor pump
Failure of the controller
・
Replace the controller
Failure of the encoder
・
Replace the motor pump
Failure of the controller
・
Replace the controller
E12
Overspeed
Motor rotation speed exceeded
120% of the maximum
rotational speed
Noise
・
Add a noise filter
Power supply voltage is out of
the specification range
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
E14
Regenerative brake overload
Overload protection of
regenerative resistor is
activated.
During deceleration the braking
force is too large
・
Reduce the parameter value of "
P13 ~ P28: deceleration time
setting"
・
Reduce the value of "P05: Load
command rate at the time of
regeneration", "P06: Regenerative
load ratio command at the time of
deceleration"
The power supply voltage is low
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
Re-turn on the power when the
display is not completely
disappeared
・
Re-power when the display is
completely disappeared
E15
Undervoltage
Main circuit voltage becomes
less than DC190V
Failure of the controller
・
Replace the controller
Power supply voltage is high
・
Check the power supply voltage
in monitor mode [n12: main
circuit voltage], and make it in
the required range
Failure of the controller
・
Replace the controller
E16
Overvoltage
Main circuit voltage becomes
more than DC400V
Rapid deceleration in PQ
selection switching
・
Reduce the parameter value of "
P13 ~ P28: deceleration time
setting"
・
Reduce the value of "P05: Load
command rate at the time of
regeneration", "P06: Regenerative
load ratio command at the time of
deceleration"
Load torque is large
・
Replace the motor pump
Defects in motor control due to
the effect of noise
・
Replace the controller
E17
Motor electronic thermal
error
Overload protection is activated
by electronic thermal
Defects in motor control due to
the effect of noise
・
Add a noise filter
E18
Magnetic pole detection error
Magnetic pole detection is not
completed within the specified
time
Abnormality of the output device
・
Replace the controller
E20
Encoder disconnection
Encoder cable break
Disconnection or connection
failure of the encoder harness
・
Replace the encoder harness