PIM00411
12-13
12.6
Other functions
12.6.1
[P12: W_TM] Solenoid valve response delay time at the time of switching PQ selection
After switching the PQ pattern, it will change the pressure command or the flow rate command after a delay
determined by this parameter.
Please adjust it, if you want to change pressure or flow rate, and avoid the instability in switching solenoid valve.
PQ0
PQ1
PQ Nu mber
[P12: Solenoid valve response delay time]
Pressure
Co mmand
Flow rate
Co mmand
0
0
PH00
PH01
QH00
QH01
Display
Sign
Parameter name
Range
Factory Default
Setting
Unit
P12
W_TM
Solenoid valve response
delay time
0.00
~
9.99
0.00
sec
12.6.2
[P32: S_TM] and [P33: L_IN] Suppression of surge during start-up
When start from stopped state, increasing in the slope of the following command and output, the occurrence of
pressure surge will be suppressed.
・
Pressure command
・
Flow rate command
・
Motor output
Display
Sign
Parameter name
Range
Factory Default
Setting
Unit
P32
S_TM
Surge less start-up time
0.0
1~
9.99
0.5
sec
P33
L_IN
Motor start initial response
gain
1~
999
1
0
-