PIM00411
3-3
3.2.2
Common Specifications
(
Note 1
)
Please contact us if other kinds of oil besides mineral hydraulic oil (water-glycol) are going
to be used.
(
Note 2
)
Even in the tolerance range, if the change is + side,
there is a possibility that when
responding the regenerative overload alarm raises and the unit stops depending on the main
machine’s operating conditions and the load conditions. If the change is – side, the output
characteristics may become low.
(
Note 3
)
If its operating temperature beyond the recommended temperature range, the pressure
pulsation may increase, the discharge flow rate may reduce, but it is not a malfunction.
Hydraulic oil
(Note 1)
Dedicated mineral hydraulic oil / Wear-resistant hydraulic oil (For recommended brands,
refer to DAIKIN "Hydraulic Equipment General Catalog (HK196)".)
・
Viscosity grade: ISO VG 32 to 68
・
Viscosity range: 15 to 400 mm2/s
・
Pollution degree: NAS Class 9 or lower level
Power supply
3
φ
200V/50Hz
200V/60Hz
220V/60Hz
Power supply voltage fluctuation tolerance range is ±10%.
(Note2)
External input signal
(3ch)
Photocoupler isolation, DC24V (up to 27V) 5mA/1ch
External output signal
(relay output) (1ch)
Relay output contact capacity: DC30V 0.5A (resistance of load) 1c contact
External output signal
(dry contacts) (2ch)
Photocoupler isolation, open collector output DC24V 50mA or less / 1ch
Standard paint color
Ivory white (Munsell 5Y7.5 / 1)
Tank oil temperature
0 to 60
℃
(recommended operating temperature range: 15 to 50
℃
)
(Note3)
Operating ambient
temperature
0 to 40
℃
Storing ambient
temperature
-20 to 60
℃
Humidity
85% RH or less ( No condensation)
Height above the sea
level
1,000 m or less
Installation place
Indoor (Be sure to fasten the unit with bolts.)
Others
・
Be sure to mount a no-fuse breaker (three-pole) in main power supply circuit.
・
Make sure that the electric wiring conforms to European Norm EN60204-1.
・
If you frequently turn ON/OFF the power supply for this unit, the controller service life
will be remarkably deteriorated. If you intend to start and stop the unit at intervals of
eight minutes or less, use the start/stop signal function of this unit. However, if the start-
stop function is being used, please make sure the interval time is upto one minute or
more.
・
Be sure to connect the ground terminal.