5 Application guidelines
Installer reference guide
19
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
▪ For more information about:
▪ Optimizing the energy consumption for producing domestic hot
water, see
"8 Configuration" on page 48
.
▪ Connecting the electrical wiring of the standalone DHW tank to
the indoor unit, see the installation manual of the DHW tank.
▪ Connecting the water piping of the standalone DHW tank to the
indoor unit, see the installation manual of the DHW tank.
5.4.5
Combination: Standalone DHW tank +
Solar panels
By connecting the DHW tank to solar panels, the DHW tank can be
heated by solar energy.
For installation instructions, see the installation manual of the solar
kit and addendum book for optional equipment.
M
a
c
d
b
c.1
c.2
c.3
e
c.4
f
≥
0.5 m
a
Solar panels
b
Solar pump station
c
Solar pump station controller with temperature sensors
c1
Tank temperature sensor
c2
Return temperature sensor to solar panels
c3
Supply temperature with flow meter from solar panels
c4
Solar panel temperature sensor
d
Solar kit
e
DHW temperature sensor of the unit
f
Solenoid 2-way valve (only for UK). Obligatory for
compliance to UK building regulation G3.
5.4.6
DHW pump for instant hot water
Setup
c
f
a
b
g
h
i
a
Indoor unit
b
DHW tank
c
DHW pump
f
Shower
g
Cold water
h
Domestic hot water OUT
i
Recirculation connection
▪ By connecting a DHW pump, instant hot water can be available at
the tap.
▪ The DHW pump and the installation are field supply and the
responsibility of the installer.
▪ For more information about connecting the recirculation
connection:
▪ for integrated DHW tank, see
"7 Installation" on page 29
,
▪ for separate DHW tank, see installation manual of DHW tank.
Configuration
▪ For more information, see
"8 Configuration" on page 48
.
▪ You can program a schedule to control the DHW pump via the
user interface. For more information, see the user reference
guide.
5.4.7
DHW pump for disinfection
Setup
c
a
b
d f
e g
h
i
a
Indoor unit
b
DHW tank
c
DHW pump
d
Heater element
e
Non‑return valve
f
Shower
g
Cold water
h
Domestic hot water OUT
i
Recirculation connection
▪ The DHW pump is field-supplied and its installation is the
responsibility of the installer.
▪ For the integrated DHW tank, the temperature of the DHW tank
can be set to maximum 60°C. If applicable legislation requires
higher temperature for disinfection, you can connect a DHW pump
and heater element as shown above.
▪ If applicable legislation requires disinfection of the water piping
until the tapping point, you can connect a DHW pump and heater
element (if needed) as shown above.
Configuration
The indoor unit can control DHW pump operation. For more
information, see
"8 Configuration" on page 48
.
5.5
Setting up the energy metering
▪ Via the user interface, you can read out the following energy data:
▪ Produced heat
▪ Consumed energy
▪ You can read out the energy data:
▪ For space heating
▪ For space cooling
▪ For domestic hot water production
▪ You can read out the energy data:
▪ Per month
▪ Per year
INFORMATION
The calculated produced heat and consumed energy are
an estimation, the accuracy cannot be guaranteed.
5.5.1
Produced heat
INFORMATION
The sensors used to calculate the produced heat are
calibrated automatically.
▪ Applicable for all models.
▪ The produced heat is calculated internally based on:
▪ The leaving and entering water temperature
▪ The flow rate
▪ The power consumption of the booster heater (if applicable) in
the domestic hot water tank