7 Installation
Installer reference guide
32
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
1
2
5×
3
3
3
Put the installation pattern (see packing) on the wall and follow
the steps as shown below.
2×
2
1
3
4
4
Lift the unit.
1
2
5
Tilt the top of the unit against the wall at the position of the 2
inserted screws.
6
Hook the unit against the wall.
2
1
2×
3
2×
7
Assemble the unit.
1
2
1
2
2
2
3
5×
7.4.4
To install the drain pan kit
If a drain pan kit (EKHBDPCA2) is required, install it before
connecting the refrigerant and water pipes and the electrical wiring.
To install, see the installation manual of the drain pan kit.
7.5
Connecting the refrigerant piping
7.5.1
About connecting the refrigerant piping
Before connecting the refrigerant piping
Make sure the outdoor and indoor unit are mounted.
Typical workflow
Connecting the refrigerant piping involves:
▪ Connecting the refrigerant piping to the outdoor unit
▪ Connecting the refrigerant piping to the indoor unit
▪ Installing oil traps
▪ Insulating the refrigerant piping
▪ Keeping in mind the guidelines for:
▪ Pipe bending
▪ Flaring pipe ends
▪ Brazing
▪ Using the stop valves
Содержание Altherma ERLQ011-014-016CA
Страница 144: ...4P384974 1 2015 01 Copyright 2015 Daikin ...