14 Technical data
Installer reference guide
119
ERHQ+ERLQ011~016 + EHBH/X11+16CB
Daikin Altherma – Low temperature split
4P384974-1 – 2015.01
Heating only type
Reversible type
Indoor units
16/16
16/16
Outdoor units
ERLQ011CAV3
ERLQ014CAV3
ERLQ016CAV3
ERLQ011CAV3
ERLQ014CAV3
ERLQ016CAV3
Fin
Type
WF fin
Treatment
Anti-corrosion treatment (PE)
Fan
Type
Propeller
Quantity
2
Air flow rate (nominal at 230 V)
—
Discharge direction
Horizontal
External static pressure
(maximum)
—
Motor
Quantity
2
Model
Brushless DC motor
Position
—
Speed
(nomin
al at
230 V)
Nr. of
steps
8
Cooling
—
780 rpm
Heating
740 rpm
750 rpm
760 rpm
740 rpm
750 rpm
760 rpm
Output
70 W
Drive
Direct drive
Compressor
Quantity
1
Motor
Model
JT100G-VD@B2
Type
Hermetically sealed scroll compressor
Speed
—
Output
2200 W
Starting method
Inverter driven
Crankcase
heater
33 W
Operation range
(a)
Heating
(outdoor unit)
(b)
Minimum
–25°C DB
Maximum
35°C DB
Cooling
Minimum
—
10°C DB
Maximum
—
46°C DB
Domestic hot
water (outdoor
unit)
(c)
Minimum
–20°C DB
Maximum
35°C DB
Sound level
Nominal –
Heating
(d)
Sound power
64 dBA
64 dBA
66 dBA
64 dBA
64 dBA
66 dBA
Sound
pressure
(f)
51 dBA
51 dBA
52 dBA
51 dBA
51 dBA
52 dBA
Nominal –
Cooling
(e)
Sound power
—
64 dBA
66 dBA
69 dBA
Sound
pressure
(f)
—
50 dBA
52 dBA
54 dBA
Night quiet -
Heating
Sound
pressure
(f)
42 dBA
42 dBA
43 dBA
42 dBA
42 dBA
43 dBA
Night quiet -
Cooling
Sound
pressure
(f)
—
45 dBA
45 dBA
46 dBA
Refrigerant
Type
R410A
Charge
3.4 kg
Control
Expansion valve (electronic type)
Nr. of circuits
1
Refrigerant oil
Type
Daphne FVC68D
Charged volume
1.5 l