6/8
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[4-03]
R/W
0: Limited
1: No limit
2: Most optimum
3: Optimum
4: Only legionella
A.8
[4-04]
R/W
0: Continuous pump operation
1: Intermittent pump operation
2: No protection
A.8
[4-05]
0
A.8
[4-06]
0/1
A.8
[4-07]
R/W
0: No
1: Yes
A.8
[4-08]
0
A.8
[4-09]
1
A.8
[4-0A]
0
A.8
[4-0B]
R/W
1~10°C, step: 0,5°C
1°C
A.8
[4-0D]
R/W
1~10°C, step: 0,5°C
3°C
A.8
[4-0E]
Is the installer on site?
R/W
0: No
1: Yes
A.8
[5-00]
R/W
0: Allowed
1: Not allowed
A.8
[5-01]
R/W
-15~35°C, step: 1°C
-4°C
A.8
[5-02]
R/W
0: Disabled
1: Enabled
A.8
[5-03]
R/W
-15~35°C, step: 1°C
0°C
A.8
[5-04]
R/W
0~20°C, step: 1°C
10°C
A.8
[5-05]
50
A.8
[5-06]
50
A.8
[5-07]
50
A.8
[5-08]
50
A.8
[5-09]
20
A.8
[5-0A]
20
A.8
[5-0B]
20
A.8
[5-0C]
20
A.8
[5-0D]
R/W
R/O (*3)(*4)
0~5
1: 1P,(1/1+2)
4: 3PN,(1/2)
5: 3PN,(1/1+2)
A.8
[5-0E]
1
A.8
[6-00]
R/W
2~20°C, step: 1°C
2°C
A.8
[6-01]
R/W
0~10°C, step: 1°C
2°C
A.8
[6-02]
R/W
0~10 kW, step: 0,2 kW
3 kW
A.8
[6-03]
R/W
0~10 kW, step: 0,2 kW
3 kW
A.8
[6-04]
R/W
0~10 kW, step: 0,2 kW
0 kW
A.8
[6-05]
0
A.8
[6-06]
0
A.8
[6-07]
0
A.8
[6-08]
R/W
2~20⁰C, step: 1⁰C
10⁰C
A.8
[6-09]
0
A.8
[6-0A]
R/W
30~[6-0E]⁰C, step: 1⁰C
55⁰C
A.8
[6-0B]
R/W
30~min(50, [6-0E])⁰C, step: 1⁰C
45⁰C
A.8
[6-0C]
R/W
30~min(50, [6-0E])⁰C, step: 1⁰C
45⁰C
A.8
[6-0D]
R/W
0: Reheat only
1: Scheduled
2: Scheduled only
A.8
[6-0E]
R/W
If [E-07]=0
40~75°C, step: 1°C
60°C
If [E-07]=5
40~80°C, step: 1°C
80°C
A.8
[7-00]
R/W
0~4⁰C, step: 1⁰C
0⁰C
A.8
[7-01]
R/W
2~40⁰C, step: 1⁰C
2⁰C
A.8
[7-02]
R/O
0: 1 LWT zone
1: 2 LWT zones
A.8
[7-03]
2.5
A.8
[7-04]
0
A.8
[7-05]
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
A.8
[8-00]
1 min
A.8
[8-01]
R/W
5~95 min, step: 5 min
30 min
A.8
[8-02]
R/W
0~10 hour, step: 0,5 hour
3 hour
A.8
[8-03]
R/W
20~95 min, step: 5 min
50 min
A.8
[8-04]
R/W
0~95 min, step: 5 min
95 min
A.8
[8-05]
R/W
0: No
1: Yes
Allow modulation of the LWT to control the room temp?
Boiler efficiency
--
Maximum running time for domestic hot water operation
Anti-recycling time
Booster heater delay timer
Additional running time for the maximum running time.
What is the maximum temperature set point?
Domestic hot water booster heater overshoot temperature
Domestic hot water booster heater hysteresis
How many leaving water temperature zones are there?
--
--
What is the hysteresis to be used in reheat mode
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
What is the capcity of the booster heater?
What is the capacity of the backup heater step 1?
What is the capacity of the backup heater step 2?
--
--
--
--
--
What type of backup heater installation is used?
--
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
--
--
--
--
--
--
Automatic cooling/heating changeover offset.
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
What is the equilibrium temperature for the building?
Space heating priority.
Space heating priority temperature.
Set point correction for domestic hot water temperature
-- (Do not change this value)
Enable the second step of the backup heater?
--
--
--
Automatic cooling/heating changeover hysteresis.
Operation permission of the booster heater
How to protect the water pipes from freezing
--
4P522033-1A - 2018.06
(*1) *B*CAV3/CAW1_
(*2) *D*CAV3/CAW1_
(*3) *B*CA3*_(*4) *D*CA3*
Содержание Altherma EBLQ011CAV3
Страница 140: ...ESIE18 04 2019 02 Copyright 2019 Daikin...