21
No.
Name
5
–
6
Save and exit
7
Working indicator light. When metal is detected, the alarm light on the door
panel for the corresponding zone is on, and the indicator light grows green
from red.
8
Program
9
Power button
4.2.2 Remote Controller
For details, see "4.1.2 Remote Controller".
4.2.3 Device Operations
4.2.3.1 Function Description
Press
to select a function, and press
and
to enter the value as needed.
Table 4-4 Function Description
Function
Parameter
Description
Setting password
—
Log in to the Device with the
default password (0000) and
change the password regularly.
Setting security level
H
The detection sensitivity of the
whole detector. It ranges from 1
to 99, and 80 by default.
Setting sensitivity (sensor on the left
side)
1L-6L
The detection sensitivity of
each zone. It ranges from 0 to
400, and 400 by default.
Setting sensitivity (sensor on the right
side)
1R-6R
Setting frequency
F
When multiple devices work
simultaneously, set different
frequencies for each device to
reduce mutual interference. It
ranges from 1 to 50, and 11 by
default.
Setting infrared tart-stop
1R
Infrared start-stop function is
designed for longer service life
of the Device. You can set four
modes of the light alarm: Start
the front group, start the back
group, start both groups, and
close both groups. start both
groups (3) is enabled by default.