22
Function
Parameter
Description
Setting scenarios
CJ
The Device supports 72
scenarios, and every scene
corresponds to different
sensitivity levels. It is 72 by
default.
Pillar light display
Ld
Reserved function.
Battery level
dc
Reserved function.
Selecting automatic frequency
hopping
CF
The Device can adjust the
frequency automatically. 1
means enabled, and 0 means
disabled. It is 0 by default.
Managing Zone
FL
The door panel can be set to 18,
12 or 6 zones according to the
door body. It is 18 by default.
Setting alarm
Setting alarm tone
yd
There are 99 built-in tones, and
it is 2 by default.
Setting alarm
volume
y
Adjust the alarm volume. It
ranges from 0 to 99. The bigger
the number is, the higher the
volume is. It is 2 by default.
Setting alarm
duration
d
It is the time that an alarm lasts.
It ranges from 0 to 99. The
bigger the number is, the
longer the duration is. It is 1 by
default.
4.2.3.2 Password Setting
4.2.3.2.1 Login
You can log in to the device with the default password (000000).
Step 1
Connect the power supply, press
.
Step 2
Press
.
P 0000
is displayed.
Step 3
Enter the password. It is 0000 by default.
Press
to select the digit from 0 to 9 and press
to set the next digit.
The password consists of 4 digits.
Step 4
Press
to save the setting.
If the setting failed, the error code
E 0000
will be displayed.