104
Figure 6-26 Port
Step 2
Configure parameters.
●
0–1024, 1900, 3800, 5000, 5050, 9999, 37776, 37780–37880, 39999, 42323 are occupied
for specific uses.
●
Do not use the same value of any other port during port configuration.
Table 6-14 Port parameter description
Parameter
Description
Max Connection
The maximum number of users (web client, platform client or mobile
phone client) that can connect to the Camera simultaneously, the
value is 10 by default.
TCP Port
Port of transmission control protocol. The value is 37777 by default.
UDP Port
User datagram protocol port, the value is 37778 by default.
HTTP Port
HTTP communication port. The default value is 80. If you have
modified the default value, when logging in through a browser, you
need to add the latest port number to the end of IP address.