PILOT’S OPERATING HANDBOOK
SECTION 3
EMERGENCY PROCEDURES
EASA Approved
Edition 0 -- October 31, 2013
Rev. 1
Page 3.3.3
”BAT AMP”
BATTERY current over 50A while on ground.
After starting the engine with airplane power, a battery charge above 50 amperes is normal.
CAUTION
DO NOT TAKE OFF IF BATTERY CHARGE > 50 AMPERES
If this indication remains steady at a high value, it may be due to a battery or generation system failure.