Input Parts
Control Object
Contents
1. D-Sensor
2. Initial Power Supply
1. Defrosting Mode
1. If D-Sensor ≤ 3.5℃ when the initial power supply begins, Defrosting mode will start.
2. Defrosting is made per D-Sensor.
3. When in initial Defrosting, Comp is delayed by 6min.
6-6 Initial Defrosting
Input Parts
Control Object
Contents
1.Front PCB
1. Electronic Units
1. Starting: Press “Fridge Adjustment” + “Freezing Adjustment” 10 times in the “Locked” state.
2. Control Method: Comp & F/C-Fan continuous operation. R Damper Open
3. Operation Display: “Co” displayed at Error Display Mode (Refer to Error Display)
4. Cancellation: Automatically canceled 10 hr after starting
6-7 Short Circuit Operation
Input Parts
Control Object
Contents
1.Comp
6-8. Comp RPM Control ( Inverter compressor model only )
1. Comp RPM is changed per RT-Sensor & Set operation state
Temperature Condition
~29℃
29℃ ~ 35℃
35℃ ~ 41℃
41℃ ~
Normal Operation
1800 RPM
2550 RPM
3600 RPM
3990 RPM
Load Response1
2550 RPM
3600 RPM
3990 RPM
3990 RPM
Load Response2
3990 RPM
3990 RPM
3990 RPM
3990 RPM
Quick Operation
3600 RPM
3600 RPM
3600 RPM
3990 RPM
Short Circuit Operation
3990 RPM
3990 RPM
3990 RPM
3990 RPM
2. For 5 min. after an initial power supply, 1800RPM (lowest speed) operation
N/A
22
Содержание Q600 series
Страница 7: ...3 1 Normal Compressor 3 Wiring Diagram 6...
Страница 8: ...3 2 Inverter Compressor 7...
Страница 9: ...4 1 FRQ 19D Dispenser only 4 External Size and Names of the Refrigerator 8...
Страница 10: ...4 2 FRQ 19F Dispenser H bar 9...
Страница 30: ...Contents 3 Ice Separation Mode 29...
Страница 61: ...INVERTER BOX COMPRESSOR 60 INVERTER Compressor VESD11C INVERTER Compressor ENV4A5G L2B...
Страница 101: ...10 4 How to install Water Line Dispenser Models only External Filter Type 100...
Страница 102: ...101...