7-2-2. No / Weak Refrigeration (Food not cooled / Slow cooling)
Solve Pertinent Error
Code Problem
Start
No Error Code on
Front-PCB
?
R-damper Starting
Normal?
Fridge Gasket Not
Fixed?
N
Y
N
Y
Y
N
Y
N
Load too close to R-
Sensor?
Too many Door
Opening?
※ Error Code
R1 : R-Sensor Disconnection/Short Circuit (Check R-Sensor)
C1 : Abnormal Cycle (Comp, Refrigerant Leak)
F3 : Abnormal Return from Defrosting (Check Temperature
Fuse, Defrosting Heater)
Wire Connection
Good?
Replace R-damper
Check Wire
Connection
Remove Load & Explain
Explain against too many Door opening
N
Y
N
Freezer Normal?
Refer to repairing bad
freezing
N
Reassemble the Door
Gasket Not Fixed
or Any Break?
An upper Gap due
to the Door
Drooping?
Fix Gasket & Break
Y
N
Y
N
R-Sensor Normal?
Replace R-Sensor/
Check Connector
Y
Y
N
Have them use in Freezer “Strong” Mode,
*
Jumper Cutting in
Main PCB to prevent
weak cooling
Option 1 : J1 Cutting 1.5℃ Down
Option 2 : J1 & J2 Cutting 3.0℃ Down
Y
※ If R-Sensor is Blocked, it cannot normally sense
Temperature and poor cooling may result in.
※ Error Mode
Check Method
(Dispenser type)
Press “Water” Button 5 times with “Freezing
Adjustment” Button pressed to start
※ Error Mode
Check Method
(Basic type)
Press
“Lock”
Button
5
times
with
“Freezing Adjustment” Button pressed to
start.
45
Содержание Q600 series
Страница 7: ...3 1 Normal Compressor 3 Wiring Diagram 6...
Страница 8: ...3 2 Inverter Compressor 7...
Страница 9: ...4 1 FRQ 19D Dispenser only 4 External Size and Names of the Refrigerator 8...
Страница 10: ...4 2 FRQ 19F Dispenser H bar 9...
Страница 30: ...Contents 3 Ice Separation Mode 29...
Страница 61: ...INVERTER BOX COMPRESSOR 60 INVERTER Compressor VESD11C INVERTER Compressor ENV4A5G L2B...
Страница 101: ...10 4 How to install Water Line Dispenser Models only External Filter Type 100...
Страница 102: ...101...