7-10-5. Order of CYCLE(R-600a) Repair Work (COMP Replacement)
- Connect Refrigerant
Discharge Hose
and draw it to
Outdoors
- Removal Time: 7min.
Stage 1.
Removal of R-600a
Refrigerant
Stage 2.
Removal of Residual
Refrigerant
Stage 3.
Comp/Dryer Replacement
& Pipe Welding
Stage 4.
Charging Ripple Welding
Stage 5.
Evacuation
Stage 6.
Injection of R-600a
Refrigerant
- Connect a vacuum
pump at the end of the
Refrigerant Discharge
Hose and remove the
residual Refrigerant
- Removal Time: 10min.
- Replace Comp & Dryer
- Weld each pipe
- Copper-Copper: 3%
Welding
- Copper-steel: 30%
Welding
- Charging Ripple
Welding
※Be sure to remove the
ripple cover and the
gas injection cover
before welding is done.
(Refer to Details)
- Connect Manifolder
Gauge to check
the evacuation.
- Evacuation Time:
60~80min.
- Inject Refrigerant to a
normal operation state.
- Removal Time: 10min.